Prodys S.L. Tel: +34 91 6896880
Θ
Fax: +34 91 6943777
Θ
Email:
Θ
Web:
www.prodys.com
Page 79
Voltage Out of Range 12 v Main:
The voltage from the main power supply
(AC/DC) is out of range.
Voltage Out of Range 12 v Backup:
The voltage from the backup power
supply is out of range
.
Voltage Out of Range 3.3 v System:
The voltage from the 3.3 DC/DC
converter is out of range
.
Voltage Out of Range 5 v System:
The voltage from the 5 DC/DC
converter is out of range
.
Temperature Out of Range:
The temperature is out of range
13
.
Fan Failure:
The fun is activated if the internal temperature is over 34º. The
Fan Failure alarm will be activated if the fun doesn’t work when the
temperature is over this threshold.
LAN NOT Present:
Not physical level detected in the LAN port.
LAN Traffic:
The LAN traffic is higher than the 90% of the capacity of the
network.
No Audio input level detected
: No audio is present on the input. A
threshold and a time period can be defined to activate the alarm.
ISDN NOT Present
: Not physical level detected in the ISDN port.
X21 Line Not Present
: Not physical level detected in the X21 port.
Decoder 1/2 Framed Lost
: The Line is connected but the decoder is not
framed anymore. The alarm will be activated also if the unit is turned off. In
13
The temperature is above 50ºC.
Содержание IP Family
Страница 1: ...Nov 08 Rev 6 0...
Страница 77: ...Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Page 77...
Страница 82: ...Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Page 82...
Страница 87: ...Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Page 87...
Страница 133: ...Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Page 133...