Prodys S.L. Tel: +34 91 6896880
Θ
Fax: +34 91 6943777
Θ
Email:
Θ
Web:
www.prodys.com
Page 41
IV.2
System Configuration
Grouped here are functions that affect the general operation of the unit.
<Loop>:
This sets up an Encoder-Decoder loop. Its purpose is to help the
user to check audio connections before streaming. The loop takes place in
accordance with the encoder configuration in place at that moment.
<PLL>:
This is a special option that allows you to select the PLL reference
clock when NET = IP.
<Redial>:
It is possible to configure a number of redials for attempting the
first call of this communication. The Prodys IP Family codec will try the
connection in the following cases:
1.- The unit is trying the connection for the first time.
2.- The unit was connected and lost the connection because the line
dropped or the line was disconnected from the other end.
<Keypad>
: This option allows the user to lock automatically the frontal panel
keypad.
<Monitor>:
This option allows the user to hide or display additional
information on the main window:
-
VU meters: Indicates audio levels.
-
System: Monitor voltages, temperatures, and fan operation.
-
Streaming: Shows clock-sync algorithm operation and Buffer
Occupation Graph (Real Time Network Analyzer). This algorithm
comes into scene when receiving audio over IP. This display is
active when the audio data is "framed" - Under normal
circumstances the indicator should be in the middle Green area.
Содержание IP Family
Страница 1: ...Nov 08 Rev 6 0...
Страница 77: ...Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Page 77...
Страница 82: ...Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Page 82...
Страница 87: ...Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Page 87...
Страница 133: ...Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Page 133...