Prodigy
r
Manual Powder Spray Gun
13
Part 1053680E05
E
2007 Nordson Corporation
J3
J2
J1
1
2
3
4
5
6
1
2
3
4
2
1
3
J1
J2
J3
Ground
(N/C)
J1-1
J1-2
J1-3
J1-4
J1-5
J1-6
J3-4
J3-3
J3-2
J3-1
J2-1
J2-3
J2-2
SPRAY T
COMMON
+VDC
uA FEEDBACK
PATTERN T
GND
SHIELD
CABLE GND
IC WIRE
MOLDED INTO
STRAIN RELIEF
+VDC
uA FEEDBACK
COMMON
SPRAY T
COMMON
PATTERN T
Figure 13
Control Cable Continuity Tests
Trigger Switch Continuity Test
Disconnect the control cable from the trigger
switch, as described in Cable Replacement on
page 14.
Test for continuity using the following table and
Figure 14.
Pins
Trigger
Results
1 and 2
Off (Open)
No continuity
1 and 2
On (Closed)
Continuity
2 and 3
Off (Open)
No continuity
2 and 3
On (Closed)
Continuity
Pin
2
1
4
3
J3
1 Spray Trigger
2 Common
3 Pattern Control Trigger
4 N/C
Function
Figure 14
Trigger Switch Continuity Test