56 PRODIGIT
GRAPHT
Syntax: GRAPHT {SP} {0~100} {; | NL}
Description: Set the Inrush current measurement mode waveform displacement time
Return: Setting range 0~100.00ms.
REMote
Syntax: REMote {; | NL}
Description: Set to remote control lock button
LOCAL
Syntax: LOCAL {; | NL}
Description: Set to stand-alone mode
CLEAR
Syntax: CLEAR {; | NL}
Description: Clear voltage, current, watt maximum and minimum
ONTIME
Syntax: ONTIME {SP} {0.200~600.000} {; | NL}
Description: Set switch on hold time (Cycling Mode)
OFFTIME
Syntax: OFFTIME {SP} {0.200~600.000} {; | NL}
Description: Set switch off hold time (Cycling Mode)
REPEAT
Syntax: REPEAT {SP} {1~9999} {; | NL}
Description: Set the number of switch cycle tests (Cycling Mode)
SCALE
Syntax: SCALE {SP} {1~10000.00} {; | NL}
Description: Set Ext input scale
LOCK
Syntax: LOCK {SP} {ON | OFF | 0 | 1} {; | NL}
Description: Set to lock data
AUTOUP
Syntax:
AUTOUP {SP}{0 | 1 | ON | OFF} {; | NL}
Description: Set automatic upshift function, 0 or OFF= closed
,
1 or ON=
open
(Standby Mode & Accumulator & Data Logger Mode)
THD
Syntax: THD {SP} {0 | 1} {; | NL}
Description: Set THD mode,0=THDR,1=THDF
GRAPH
Syntax: GRAPH {SP} {0 | 1} {; | NL}
Description: Set Inursh Graph mode,0=AVG,1=OR