15-16
Redundancy (Switch 8212zl)
Hotswapping Management Modules
When the Standby Module is not Available
If you have disabled redundancy with the
no redundancy management-module
command, or the standby module failed selftest, the
Dwn
LED will not turn
green to indicate it is OK to hotswap out the active management module.
N o t e
If you remove the active management module without pressing the
MM
Shutdown
button, any files that may have been in the process of
synchronizing will not finish synchronizing to the standby module and all file
transfer is aborted.
Hotswapping In a Management Module
If another management module is hotswapped in while there is an active
management module booted up, the newly hotswapped management module
becomes the standby module. It partially boots up and heartbeats are sent
back and forth with the active management module. No negotiating is needed
as to which module will become the active management module as there is
already a functioning active management module. However, these conditions
must be met to determine if the hotswapped module can become a standby
management module:
■
The hotswapped module must pass selftest
■
Redundancy is not administratively disabled (using the
no redundancy
management-module
command). If the active management module’s config
file has redundancy administratively disabled, the hotswapped manage-
ment module goes into “offline” mode.
Software Version Mismatch Between Active
and Hotswapped Module
Sometimes the software version in the hotswapped module may not match
the software version in the active module. In these cases the following occurs:
1.
The active module sends the primary and secondary images in flash to the
hotswapped module.
2.
The module that was hotswapped in then reboots if necessary to primary
or secondary flash, whichever matches (if it doesn’t match already).
3.
After the hotswapped management module finishes booting, it is sent the
config and other critical files from the active management module.
4.
The hotswapped management module goes into standby mode and is
ready to take over in case of a switchover.
3500-5400-6200-8200-MCG-Jan08-K_13_01.book Page 16 Monday, January 28, 2008 10:04 AM
Содержание 3500yl Series
Страница 2: ......
Страница 26: ...xxiv 3500 5400 6200 8200 MCG Jan08 K_13_01 book Page xxiv Monday January 28 2008 10 04 AM...
Страница 730: ...20 Index 3500 5400 6200 8200 MCG Jan08 K_13_01 book Page 20 Monday January 28 2008 10 04 AM...
Страница 731: ......
Страница 732: ...Copyright 2005 2008 Hewlett Packard Development Company L P January 2008 Manual Part Number 5992 3059...