9-5
Time Protocols
SNTP: Viewing, Selecting, and Configuring
Table 9-1. SNTP Parameters
Menu: Viewing and Configuring SNTP
To View, Enable, and Modify SNTP Time Protocol:
1.
From the Main Menu, select:
2. Switch Configuration...
1. System Information
SNTP Parameter Operation
Time Sync
Method
Used to select either SNTP, TIMEP, or None as the time synchronization method.
SNTP Mode
Disabled
The Default. SNTP does not operate, even if specified by the Menu interface
Time Sync Method
parameter or the CLI
timesync
command.
Unicast
Directs the switch to poll a specific server for SNTP time synchronization. Requires at least one server
address.
Broadcast
Directs the switch to acquire its time synchronization from data broadcast by any SNTP server to the
network broadcast address. The switch uses the first server detected and ignores any others.
However, if the Poll Interval expires three times without the switch detecting a time update from the
original server, it the switch accepts a broadcast time update from the next server it detects.
Poll Interval
(seconds)
In Unicast Mode: Specifies how often the switch polls the designated SNTP server for a time update.
In Broadcast Mode: Specifies how often the switch polls the network broadcast address for a time
update.
Value between 30-720 seconds.
Server Address
Used only when the
SNTP Mode
is set to
Unicast
. Specifies the IP address of the SNTP server that
the switch accesses for time synchronization updates. You can configure up to three servers; one
using the menu or CLI, and two more using the CLI. Refer to “SNTP Unicast Time Polling with Multiple
SNTP Servers” on page 9-25.
Server Version
Default: 3; range: 1 - 7. Specifies the SNTP software version to use, and is assigned on a per-server
basis. The version setting is backwards-compatible. For example, using version 3 means that the
switch accepts versions 1 through 3.
Priority
Specifies the order in which the configured servers are polled for getting the time. Value is between
1 and 3.
3500-5400-6200-8200-MCG-Jan08-K_13_01.book Page 5 Monday, January 28, 2008 10:04 AM
Содержание 3500yl Series
Страница 2: ......
Страница 26: ...xxiv 3500 5400 6200 8200 MCG Jan08 K_13_01 book Page xxiv Monday January 28 2008 10 04 AM...
Страница 730: ...20 Index 3500 5400 6200 8200 MCG Jan08 K_13_01 book Page 20 Monday January 28 2008 10 04 AM...
Страница 731: ......
Страница 732: ...Copyright 2005 2008 Hewlett Packard Development Company L P January 2008 Manual Part Number 5992 3059...