Selection of long-distance line
In-/Output of the control system
Address and port of the module with the control lines
In-/Output AF
Address and port of the module with the AF long-distance lines
Note!
In the case of long-distance lines that are connected by means of
, the specification
for the control system and the AF are identical.
In the case of long-distance lines that are connected by means of the analog module
, addresses
and ports may differ!
Selection xxx - Amplifier
Activated amplifier
Address and port of the amplifier (
) (1 to 4
amplifiers simultaneously)
AcknowlRelay
Address of the relay module (4IOS, 4LSL) with generation of
acknowledgment The ports of the relay module are permanently linked to
the amplifier fields. (Example: 1. Amplifier = 1st port of the relay module,
etc.)
Acknowledgment processing
AND = PA acknowledgment of all lines must be detected
OR = PA acknowledgment of one line must be detected
External = no connection with relay module, PA acknowledgment takes
place by means of
Flag
Acknowledgment flag
[IN] to trigger a PA acknowledgment by an external criterion
Note!
The
Acknowledgment flag
is only in the setting
Acknowledgment processing
Extern
ready.
Busy
flag
and
Acknowledgment flag
are not available simultaneously.
Flag (NAND)
[IN] The program can be turned off by this flag or switching on can be
prevented.
Flag (OR)
[IN] The program can be switched on by this flag. It is possible to take
over AF channels.
Flag (OUT) 1/2
[OUT] The flag is switched on if the program is activated. This enables
further programs to be activated for adaptation to specific requirements.
It is possible to hand over the AF channel in use.
Busy flag
[IO]
Flag
for processing of Busy status