Terminal Block
Installation -
2
Sensor/Alarm
Input
Relay Out
1
2
2
Sensor/Alarm Input
- It connects to IR sensor, IrDA sensor or door switch. If the
sensor is activated, it can activate to move camera to the
specific angle and to connect the alarm device.
- A cable of the sensor should connect to input 1 or 2, and
the other should be connected to ‘COM’ slot.
- The sensor types are normal open and normal close.
Relay Out
- It connects to the alarm lights, siren or lamps.
- The sensor types are normal open and normal close.
1
Out
Out
N.C
Activation
Activation
N.O
,Q
&20
,Q
&20
,Q
&20
,Q
&20
In
COM
<Inside of terminal block: Activation type of alarm in/out N.O. / N.C.>
Output voltage is high state when sensor is
activated.
Output voltage is high state when sensor is not
activated.
Normal Open
(N.O)
Normal Close
(N.C)
2
nd
Video Output
Video out check the screen during installation.
3
Power
2
nd
Video Output
BNC Video
4
3
4
5
Power
- Please check the correct rated power.
- The rated power is marked on the bottom of the camera.
RS-485 Communication (DVR/Keyboard)
For PTZ control, connect this line to keyboard and DVR.
To control multiple cameras at the same time, RS-485
communication lines of them are connected in parallel as
shown below.
RS-485 Slot
Alarm In/Output Slot
2
nd
Video Output Slot
Power Input Slot
RS-485
(Keyboard Controller/DVR)
5
Keyboard Controller/DVR
Camera 1
Camera 2
Camera n
a