background image

7

TECHNICIAN SETUP MENU

Fahrenheit/Celsius Display

12 or 24 Hour Time

Gas or Electric Setup

Gas:

 For systems that control the fan 

during a call for heat, put the fan 
operation switch to the 

GAS

 position.

Electric: 

The thermostat operation 

switch should be put in the 

ELEC

 

position. This setting allows the 
thermostat to operate the fan when 
the fan relay is connected to the 

G

 terminal.

Select 

F

 or 

C

 with the jumper pin on the 

back of the thermostat.  

F

 is for 

Fahrenheit and 

C

 is for Celsius.

12 or 24 hour (military time) can be 
selected with the jumper pin.

Important:

The 

RESET

 button must be pressed 

after changing any switch or jumper 
pin setting. Batteries must be 
installed for this operation.

12 or 24 hour 

jumper pin

Select 

F

 or 

C

 

with the jumper pin

Reset button

Содержание TRUE COMFORT III T605-2

Страница 1: ...cian Setup Technician Setup Menu Mounting and Battery Installation Programming the Thermostat Programming the Thermostat cont Specifications Table of Contents Thermostat Applications Guide Page Batter...

Страница 2: ...are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where there might be conceal...

Страница 3: ...Private Label Badge 6 7 1 2 3 4 5 LCD 1 System operation indicators ON will display when the COOL or HEAT is on NOTE The compressor delay feature is active if ON is flashing The compressor will not t...

Страница 4: ...Pro1 s products are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and prope...

Страница 5: ...when the thermostat is powered by batteries Wire specifications Use shielded or non shielded 18 22 gauge thermostat wire PRO1 Tips Wiring Terminal Designations If you are replacing a thermostat make...

Страница 6: ...C W G C L2 L1 HOT R HEAT RELAY FAN RELAY COMPRESSOR RELAY 6 2 1 FAN RELAY COMPRESSOR RELAY 6 2 HEAT RELAY FAN RELAY 6 2 Typical 1H 1C heat pump system C L2 L1 HOT R HEAT CHANGE OVER VALVE FAN RELAY CO...

Страница 7: ...s setting allows the thermostat to operate the fan when the fan relay is connected to the G terminal Select F or C with the jumper pin on the back of the thermostat F is for Fahrenheit and C is for Ce...

Страница 8: ...ycles and a larger swing setting will cause fewer cycles The heating swing setting is adjustable from 04 F to 20 F For example A swing setting of 05 F will turn the heating on at approximately 0 5 F b...

Страница 9: ...9 MOUNT THERMOSTAT BATTERY INSTALLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place...

Страница 10: ...eps below to set the day of the week and current time Press TIME Day of the week will be flashing Use the or key to select the current day of the week Press TIME The current hour is flashing Use the o...

Страница 11: ...for the weekday setting Time is flashing Use the or key to make your time selection for the weekday WAKE time period Press PROGRAM The setpoint temperature is flashing Use the or key to make your set...

Страница 12: ...ting is adjustable from 0 2 F to 2 0 F Cooling is adjustable from 0 2 F to 2 0 F 18 to 30 VAC NEC Class II 50 60 Hz for hardwire common wire Battery power from 2 AA Alkaline batteries 32 to 105 0 to 4...

Отзывы: