background image

3

Important:

The low battery indicator is displayed 
when the AA battery power is low. If 
the user fails to replace the battery 
within 21 days, the thermostat 
display will only show the low battery 
indicator as a final warning before the 
thermostat becomes inoperable.

Getting to know your thermostat

2

Fan Switch

3

System Switch

4

Easy Change Battery Door

5

Setpoint Buttons

6

User Buttons

7

Universal Private Label Badge

6

7

1

2

3

4

5

LCD

1

System operation 

indicators:

 

ON

 will 

display when the 

COOL 

or 

HEAT 

is on.

NOTE: 

The compressor delay 

feature is active if 

ON

 is 

flashing. The compressor will 

not turn on until the 5 minute 

delay has elapsed.

Days of the 

week and time

Low Battery Indicator:

 

Replace batteries when 

indicator is shown.

Indicates the 

current room 

temperature.

Displays the user 

selectable setpoint 

temperature.

HOLD

 is displayed when 

thermostat program is 

permanently overridden.

Programmable 

Time Periods:

 

This thermostat has 

4 programmable time 

periods per day. 

Wake, Leave, Return, Sleep

Содержание TRUE COMFORT III T605-2

Страница 1: ...cian Setup Technician Setup Menu Mounting and Battery Installation Programming the Thermostat Programming the Thermostat cont Specifications Table of Contents Thermostat Applications Guide Page Batter...

Страница 2: ...are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where there might be conceal...

Страница 3: ...Private Label Badge 6 7 1 2 3 4 5 LCD 1 System operation indicators ON will display when the COOL or HEAT is on NOTE The compressor delay feature is active if ON is flashing The compressor will not t...

Страница 4: ...Pro1 s products are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and prope...

Страница 5: ...when the thermostat is powered by batteries Wire specifications Use shielded or non shielded 18 22 gauge thermostat wire PRO1 Tips Wiring Terminal Designations If you are replacing a thermostat make...

Страница 6: ...C W G C L2 L1 HOT R HEAT RELAY FAN RELAY COMPRESSOR RELAY 6 2 1 FAN RELAY COMPRESSOR RELAY 6 2 HEAT RELAY FAN RELAY 6 2 Typical 1H 1C heat pump system C L2 L1 HOT R HEAT CHANGE OVER VALVE FAN RELAY CO...

Страница 7: ...s setting allows the thermostat to operate the fan when the fan relay is connected to the G terminal Select F or C with the jumper pin on the back of the thermostat F is for Fahrenheit and C is for Ce...

Страница 8: ...ycles and a larger swing setting will cause fewer cycles The heating swing setting is adjustable from 04 F to 20 F For example A swing setting of 05 F will turn the heating on at approximately 0 5 F b...

Страница 9: ...9 MOUNT THERMOSTAT BATTERY INSTALLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place...

Страница 10: ...eps below to set the day of the week and current time Press TIME Day of the week will be flashing Use the or key to select the current day of the week Press TIME The current hour is flashing Use the o...

Страница 11: ...for the weekday setting Time is flashing Use the or key to make your time selection for the weekday WAKE time period Press PROGRAM The setpoint temperature is flashing Use the or key to make your set...

Страница 12: ...ting is adjustable from 0 2 F to 2 0 F Cooling is adjustable from 0 2 F to 2 0 F 18 to 30 VAC NEC Class II 50 60 Hz for hardwire common wire Battery power from 2 AA Alkaline batteries 32 to 105 0 to 4...

Отзывы: