WIRING

5

Caution: Electrical Hazard

Failure to disconnect the power 
before beginning to install this 
product can cause electrical 
shock or equipment damage.

Warning:

All components of the control 
system and the thermostat 
installation must conform to 
Class II circuits per the NEC Code.

RH & RC terminals

For single transformer systems, leave the jumper 
wire in place between RH and RC. Remove jumper 
wire for two transformer systems.

Heat pump systems

If wiring to a heat pump, use a small piece of wire 
(not supplied) to connect terminals W and Y.

C terminal

The C (common wire) terminal does not 
have to be connected when the 
thermostat is powered by batteries.

Wire specifications

Use shielded or non-shielded 
18 - 22 gauge thermostat wire.

PRO1 Tips:

Wiring

Terminal Designations

If you are replacing a thermostat, make 

note of the terminal connections on the 

thermostat that is being replaced. In some 

cases the wiring connections will not be 

color coded. For example, the green wire 

may not be connected to the 

G

 terminal.

Loosen the terminal block screws. Insert 

wires then retighten terminal block screws.

Place nonflammable insulation into wall 

opening to prevent drafts.

1.

2.

3.

Heat relay

Compressor relay

Fan relay

Heat pump changeover valve 

energized in cooling

Transformer power for cooling

Transformer power for heating 

Heat pump changeover valve energized

in heating

Common wire from system transformer

W

Y

G

O

RC

RH

B

C

Содержание TRUE COMFORT III T605-2

Страница 1: ...cian Setup Technician Setup Menu Mounting and Battery Installation Programming the Thermostat Programming the Thermostat cont Specifications Table of Contents Thermostat Applications Guide Page Batter...

Страница 2: ...are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where there might be conceal...

Страница 3: ...Private Label Badge 6 7 1 2 3 4 5 LCD 1 System operation indicators ON will display when the COOL or HEAT is on NOTE The compressor delay feature is active if ON is flashing The compressor will not t...

Страница 4: ...Pro1 s products are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and prope...

Страница 5: ...when the thermostat is powered by batteries Wire specifications Use shielded or non shielded 18 22 gauge thermostat wire PRO1 Tips Wiring Terminal Designations If you are replacing a thermostat make...

Страница 6: ...C W G C L2 L1 HOT R HEAT RELAY FAN RELAY COMPRESSOR RELAY 6 2 1 FAN RELAY COMPRESSOR RELAY 6 2 HEAT RELAY FAN RELAY 6 2 Typical 1H 1C heat pump system C L2 L1 HOT R HEAT CHANGE OVER VALVE FAN RELAY CO...

Страница 7: ...s setting allows the thermostat to operate the fan when the fan relay is connected to the G terminal Select F or C with the jumper pin on the back of the thermostat F is for Fahrenheit and C is for Ce...

Страница 8: ...ycles and a larger swing setting will cause fewer cycles The heating swing setting is adjustable from 04 F to 20 F For example A swing setting of 05 F will turn the heating on at approximately 0 5 F b...

Страница 9: ...9 MOUNT THERMOSTAT BATTERY INSTALLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place...

Страница 10: ...eps below to set the day of the week and current time Press TIME Day of the week will be flashing Use the or key to select the current day of the week Press TIME The current hour is flashing Use the o...

Страница 11: ...for the weekday setting Time is flashing Use the or key to make your time selection for the weekday WAKE time period Press PROGRAM The setpoint temperature is flashing Use the or key to make your set...

Страница 12: ...ting is adjustable from 0 2 F to 2 0 F Cooling is adjustable from 0 2 F to 2 0 F 18 to 30 VAC NEC Class II 50 60 Hz for hardwire common wire Battery power from 2 AA Alkaline batteries 32 to 105 0 to 4...

Отзывы: