background image

4

UL/c-UL(CSA) Application Notes

CE Marking Notes

The GLC150-BG41-RSFL-24V is a UL/c-UL listed product.
(UL file No. E214883)
This unit conforms as a component to the following standards:

„

UL508

Industrial Control Equipment

„

UL1604

Electrical Equipment for Use in Class I and II Division 2 and Class III Hazardous (Clas-
sified) Locations

„

CAN/CSA-C22.2, Nos.1010

Standard for Safety of Information Technology Equipment, including Electrical Busi-
ness Equipment

GLC150-BG41-RSFL-24V (UL Registration Model : 2980036-03)

<Cautions>

If the LogiTouch is installed so as to cool itself naturally, be sure to install it in a vertical
panel. Also, be sure that the LogiTouch is mounted at least 100mm away from adjacent
structures and other equipment, otherwise, the heat generated by the LogiTouch's inter-
nal components may become higher than that allowed by UL standard requirements.
The LogiTouch shall be separated from the mains by double or reinforced insulation.

UL1604 Conditions of Acceptability and Handling Cautions:

1. Power, input and output (I/O) wiring must all be in accordance with Class I, Division 2

wiring methods, Article 501-4 (b) of the National Electrical Code, NFPA 70, or as speci-
fied in Section 18-152 of the Canadian Electrical Code for units installed within Canada,
and in accordance with that location's authority.

2. Suitable for use in Class I, Division 2, Groups A, B, C and D hazardous locations, or

nonhazardous locations only.

3. WARNING: Explosion hazard - substitution of components may impair suitability for

Class I, Division 2.

4. WARNING: Explosion hazard - do not disconnect equipment unless power has been

switched OFF or the area is known to be nonhazardous.

5. WARNING: Explosion hazard - when in hazardous locations, turn OFF power before

replacing or wiring modules.

The GLC150-BG41-RSFL-24V is a CE marked, EMC compliant product. This unit also
conforms to EN55011 Class A, EN50082-2 directives.
For detailed CE marking information, please contact your local LogiTouch distributor.

CNS Notes

The GLC150-BG41-RSFL-24V conforms as a component to the following standards:
• CNS 13438 (Class A)
<Cautions>

The LogiTouch unit is designated as Class A industrial equipment. Therefore, when
using this unit in a residential area, be careful to avoid electromagnetic interference
from nearby home appliances.

Содержание LogiTouch GLC150-BG41-RSFL-24V

Страница 1: ...s load control power turning ON an incorrect output signal or malfunction could cause an accident to occur Be sure to design a program that will ensure the safety of your system in in the event of a...

Страница 2: ...power cord is unplugged from the power supply Be sure to reattach the LogiTouch terminal block s plastic cover after completing any terminal wiring If this cover is not reattached an electric shock c...

Страница 3: ...cident Be sure to secure all wiring terminal screws in place with the designated torque Screws and terminals that become loose can cause a short circuit fire or accident Be sure that metal filings or...

Страница 4: ...st all be in accordance with Class I Division 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 or as speci fied in Section 18 152 of the Canadian Electrical Code for units inst...

Страница 5: ...This Guide Option Items sold separately LogiTouch Series User Manual GLC150 MM01 Flex Network Cables Logic Program Developer Software LogiTouch Editor Data Transfer Cable GPW CB02 50m FN CABLE2050 31...

Страница 6: ...cuit I Flex Network Connector J Flex Network LED Operation Mode 1 Controller Operation Mode 2 LED Color OFFLINE STOP Green Constant In Operation RUN Green Constant In Operation STOP Green Flashing In...

Страница 7: ...will monitor the LT unit s circuits Contact Rating 0 15A AC125V Resistance Load 0 6A DC24V Resistance Load Operating Time Set Time at 20 o C 4ms or less Recover Time Reset Time at 20 o C 4ms or less...

Страница 8: ...S 422 19 ERB Enable Receive B RS 422 20 ERB Enable Receive B RS 232C 21 CSA Clear Send A RS 422 22 ERA Enable Receive A RS 422 23 NC No Connection 24 NC No Connection 25 NC No Connection Recommended C...

Страница 9: ...nformation about Flex Network or connectable Flex Network I O units see the Flex Network User Manual 5 Installation Before installing the LogiTouch into a cabinet or panel check that the installation...

Страница 10: ...s show the four 4 fastener insertion slot locations Insert each fastener s hook into the slot and pull it back until the hook catches Insertion Slots Panel Hook Tightening the screws with too much for...

Страница 11: ...unit will result in excess noise and vibration Wherever possible use thick wires max 2 mm2 for power terminals and twist the wire ends before attaching the ring terminals Be sure to use the following...

Страница 12: ...ttaching a wire to the LogiTouch s rear face FG terminal on the Power Input Terminal Block be sure to create an exclusive ground 1 Inside the LogiTouch unit the SG Signal Ground and FG Frame Ground te...

Отзывы: