background image

10

   E

ngl

is

h

Part Numbers and Functions

E: Function switches

Use your screen editing software to set up operations associated with 

switches. For details, refer to the manual of your screen editing software.

F: Maintenance cover

G: Key switch (see page 16)

H: USB (Type A) interface

I: SD card slot

J: USB (mini-B) interface

K: 3-position enable switch (see page 16)

L: Neck strap attachment slot

M: Hanger

A hanger for temporarily hanging this product on a wall. We recommend 

using the panel, hooks and screws defined below with the Hanger.

*1 Even if the installation wall thickness is within the recommended range, 

depending on wall’s material, size, and installation location of this product 
and other devices, the installation wall could warp. To prevent warping, the 
installation surface may need to be strengthened.

N: SD card access LED (see page 11)

O: Touch pen

P: Wall adapter attachment slots

By attaching a Wall Mount Adapter (sold separately), you can secure this 

product to a panel or commercially available arm.

Q: Hand strap attachment slots

R: Insertion hole (with cover) for function switch sheet

S: Interface for direct-connect cable (with connector cover)

Panel

Panel thickness: 1 to 1.6 mm (0.04 to 0.06 in)

*1

Panel width: 14 mm (0.55 in) or more.

Hook

Diameter 7 mm (0.27 in) or less, rod-shaped or S-shaped 
hook.

Screw

M4 pan-head machine screw, which head diameter is 
7 mm (0.27 in) or less.

Содержание GP-4311HT

Страница 1: ...GP4000H Series Installation Guide NHA87487_02_EN...

Страница 2: ...tions Electrical Specifications 12 Environmental Specifications 12 Interface 13 Connection Connection with Peripheral Equipment 14 Switch 16 Attaching the Cable 17 Removing the Cable 18 Installation I...

Страница 3: ...4 English...

Страница 4: ...k at the equipment to become familiar with the device before trying to install operate or maintain it The following special messages may appear throughout this documentation or on the equipment to war...

Страница 5: ...ising out of the use of this material A qualified person is one who has skills and knowledge related to the construction and operation of electrical equipment and its installation and has received saf...

Страница 6: ...n on product models and their matching global codes please refer to the following URL http www pro face com trans en manual 1003 html Series Model name Model number 1 Description GP4000H Series GP 431...

Страница 7: ...7 Connector Cover 1 attached to this product 8 GP4000H Series Installation Guide this guide 1 9 Warning Caution Information 1 10 Emergency Stop Switch Instruction Sheet 1 This product has been careful...

Страница 8: ...LED O P see page 11 D Operation switch When the operation switch function is enabled in the screen editing software accepts inputs from the touch panel or function keys only while the operation switc...

Страница 9: ...mmended range depending on wall s material size and installation location of this product and other devices the installation wall could warp To prevent warping the installation surface may need to be...

Страница 10: ...n operation RUN Flashing In operation STOP LED fade 1 Backlight OFF Standby Mode Orange Flashing Software starting up Red ON Power is turned ON Flashing In operation Major error OFF Power is turned OF...

Страница 11: ...r 1 minute between charging and FG terminals Insulation resistance 500 Vdc 10 M or more between charging and FG terminals Physical environment Surrounding air temperature 0 40 C 32 104 F Storage tempe...

Страница 12: ...contact ENB1A a contact ENB1B Emergency stop switch stop switch output a contact EMG0A a contact EMG0B b contact EMG1A b contact EMG1B b contact EMG2A b contact EMG2B Serial signal When the RS 232C is...

Страница 13: ...and wiring refer to the corresponding cable installation guide or the GP4000H Series Hardware Manual Accessories for connecting Conversion Adapter to this product Prepare the conversion adapter or on...

Страница 14: ...C SHOCK AND FIRE When using the SG terminal to connect an external device to this product Verify that a short circuit loop is not created when you set up the system Connect the SG terminal to remote e...

Страница 15: ...n 3 Pressed to the innermost position fully closed When the switch is set at each position ON OFF status are as follows NOTE The contact is OFF when the switch is pressed to the innermost position the...

Страница 16: ...connector 1 Cable s connector cap 2 Cable connector NOTE To disconnect this cable from the connector cap be sure to hold the cable connector and pull it out If you hold other parts of this cable lock...

Страница 17: ...arrow on the cable connector 1 Lock ring 2 Small arrows Step Action 1 Turn the lock ring so that the small arrow on the lock ring is displaced from the small arrow on the cable connector Then pull ou...

Страница 18: ...apter sold separately Do not operate or wire this product while it is hung on the wall with the Hanger attached to the rear Failure to follow these instructions can result in injury or equipment damag...

Страница 19: ...llation screws included with this product 2 Remove the stop switch guard hole covers at two places beside the emergency stop switch or the stop switch 1 Stop switch guard hole covers 3 Align the three...

Страница 20: ...htly and wipe this product NOTICE EQUIPMENT DAMAGE Power off this product before cleaning it Do not use hard or pointed objects to operate the touch panel as you may damage the panel surface Do not us...

Страница 21: ...ace com trans en manual 1002 html Inquiry Do you have any questions about difficulties with your unit Please access our site any time that you need help with a solution http www pro face com trans en...

Отзывы: