background image

11

(3) Remove the screws from the two (2) terminals (L,N) and FG (Frame Ground) 

Terminal, position the Ring Terminals and reattach the screws. (Check each wire to 
make sure the connections are correct)

 

(4) Reattach the Terminal Strip’s clear plastic cover.

 

„

USB Cable Clamp Attachment Procedure

‹

Installation to USB cable 

(1) Connect the USB cable to the connector.
(2) Tighten the clamp until the cable is secured in place and insert the convex of cable 

clamp into the USB fixing hole to fix both as shown in the following figure.

‹

USB Cable Clamp Removal Feature

(1) Push in the cable clamp's stopper with a standard flat-blade screwdriver until the 

cable clamp is unlocked, and remove it.

(2) Disconnect the USB cable.

Please pay special attention to the following instructions when connecting the power cord 
terminals to the FP unit.
• If the power supply voltage exceeds the FP unit’s specified range, connect a voltage 

transformer.

• The torque required to tighten these screws are as follows:

 

Terminal Block: 0.5 to 0.6N•m.

 

FG (Frame Ground) Terminal: 0.6 to 0.7 N•m.

7

Using the USB Cable Clamp

• If the stopper will not move, press on <A> (shown in the figure) to 

free the clamp from the clamp holder.

8

Power Supply Cautions

DON’T

CONNECT

FG (Frame Ground) Terminal

USB cable

USB Cable Clamp

Stopper

<A>

USB fixing hole

Содержание FP3650-T41

Страница 1: ...l FP distributor immediately An FP3650 T41 unit needs the following software for operation As FP user manual provided by PDF media describes its details download the manual below and get the further i...

Страница 2: ...the front face of a metal panel If this unit is installed so as to cool itself naturally be sure to install it in a vertical panel Also be sure that the FP unit is mounted at least 100 mm away from an...

Страница 3: ...face F DVI D Interface Connector Connector for DVI D interface G Serial Connector Connector for serial RS 232C interface Used for sending touch panel data to the host H USB Connector Type B Connector...

Страница 4: ...setting is OFF OSD is displayed SW2 2 Dimensions 3 Dip Switches and Slide Switch Switch Setting SW1 1 Reserved Always OFF SW1 2 Display Hide the OSD SW1 3 Reserved Always OFF SW1 4 Reserved Always OF...

Страница 5: ...Clock MHz Screen Resolution Expansion H Horizontal V Vertical Display Resolution 640 400 24 827 56 000 21 053 1 6 H 1 92 V 1024 768 640 400 31 469 70 000 25 175 640 480 31 469 59 992 25 175 1 6 1024...

Страница 6: ...Horizontal synchronous signal input 14 V SYNC Vertical synchronous signal input 15 DDC CLK DDC Clock If a cable other than the specified RGB cable is used product performance cannot be guaranteed due...

Страница 7: ...D 4 NC 16 Hot Plug Detect 5 NC 17 TMDS DATA0 6 DDC Clock 18 TMDS DATA0 7 DDC Data 19 TMDS DATA0 SHIELD 8 NC 20 NC 9 TMDS DATA1 21 NC 10 TMDS DATA1 22 TMDS CLOCK SHIELD 11 TMDS DATA1 SHIELD 23 TMDS CLO...

Страница 8: ...nnector Refer to the FP 3500T 3600T 3650T series User Manual s section Cable Diagrams for each signal s direction USB Interface Type B connector Up Stream Port Pin Assignments and Signal Names for USB...

Страница 9: ...ord terminals to the power terminal block confirm that the FP s power supply is completely turned OFF via a breaker or similar unit 5 Instllation Installation gasket must be used even though it is not...

Страница 10: ...nt 60A Max Voltage Endurance AC1500V 20mA for 1 minute between charging and FG terminals Insuration Resistance DC500V 10M Min between charging and FG terminals Item Specification Surrounding Air Tempe...

Страница 11: ...ture 1 Push in the cable clamp s stopper with a standard flat blade screwdriver until the cable clamp is unlocked and remove it 2 Disconnect the USB cable Please pay special attention to the following...

Страница 12: ...it s rear face FG terminal on the AC Connector be sure to create an exclusive ground Use a grounding resistance of 100 a wire of 2mm2 or thicker or your country s applicable standard All FP Input and...

Страница 13: ...ts the current OSD value to the default value Input Source Switches Analog RGB and DVI D Auto Adjust Automatically adjusts the display position of the screen Analog RGB only Auto Gain Automatically ad...

Страница 14: ...SD will keep those values and make them effective until power off or a Reset command input Selection of the change item Applies the setting and then returns to the top menu Cancels the setting and the...

Страница 15: ...utomatically turns off Select the time period from 1 min 3 min 5 min 10 min and OFF Auto OFF function disabled Enables disables the Backlight burnout detect function Default ON When a burned out backl...

Страница 16: ...e top menu Cancels the setting and then returns to the top menu Input Source Auto Adjust Analog RGB only Applies the setting and then returns to the top menu Cancels the setting and then returns to th...

Отзывы: