3
II.- UNPACKING:
*
WHILE UNPACKING THE MACHINE TAKE SPECIAL CARE IN REMOVING THESE COMPONENTS AND MAKE SURE THAT
ALL THEM ARE ACCOUNTED FOR.
1 BASE UNIT (14) INCLUDING KNIFE(5), MOTOR(16), THICKNESS GAUGE PLATE(1), KNIFE GUARD(7)*.
1 SHARPENER BOX(6) AND CARRIAGE SUPPORT KNOB (11)*.
1. CARRIAGE ASSEMBLY INCLUDING CARRIAGE SUPPORT(12), CARRIAGE(2), CARRIAGE HANDLE(13) AND GRIP(3)*.
* NOTE:
FOR NUMERIC REFERENCE SEE FIG. 4
A.- REMOVE THE CARTON CARD BOARD PROTECTORS.
B.- TAKE OUT THE CARRIAGE ASSEMBLY.
C.- DEFINE THE PLACE TO SET THE MACHINE.
D.- TAKE OUT THE MACHINE BY LIFTING FROM THE BASE(14), (EXERCISE PROPER LIFTING METHOD, PREFERABLY DO
THIS PROCEDURE WITH TWO PERSONS).
E.- ONCE THE UNIT IS FIRMLY ON THE INTENDED PLACE OF OPERATION, REMOVE THE FOAM PROTECTOR FROM THE
KNIFE SHARPENER BOX(6).
F.- REMOVE THE ORANGE (OR BLACK) KNIFE EDGE PROTECTOR; TO DO THIS:
ROTATE THE SLICE ADJUSTING KNOB(15) COUNTER CLOCKWISE UNTIL IT STOPS.
REMOVE THE KNIFE GUARD PLATE(7) BY LOOSING THE KNIFE GUARD KNOB (NOT SHOWN) ALL ITS TRAVEL.
EXERCISE EXTREME CAUTION TO REMOVE THE KNIFE EDGE PROTECTOR BY FINDING THE PROTECTOR JOINT AND
REMOVING THE PROTECTOR BY LIFTING IT FROM THE KNIFE. (ALWAYS WEAR HAND AND FINGER PROTECTION FOR
THIS OPERATION).
ONCE THE KNIFE EDGE PROTECTOR IS REMOVED, REPLACE THE KNIFE GUARD PLATE(7) AND ASSURE IT WITH THE
KNIFE GUARD KNOB (NOT SHOWED). CLOSE THE THICKNESS GAGE PLATE(1) BY ROTATING THE SLICE ADJUSTING
KNOB(15) CLOCKWISE FULLY.
DELI MEAT SLICER
WARNING!:
TAKE SPECIAL CARE WHEN YOU TAKE APART THE KNIFE PROTECTOR,
THE KNIFE IS ALREADY SHARP FROM THE FACTORY AND WITHOUT
PROTECTOR SERIOUS INJURY MAY HAPPEN.
KSDS-12