PrismJET 54 Gen2 OPERATION MANUAL
Panel setup menu
5.1 Setup menu
169
5.1.2.1
Spitting Pass count menu
Set the frequency (spitting return count) that the print head returns to the capping unit (located) on the
origin side when setting “On” or “On Media” in the Spitting menu.
NOTE
• If you set the flushing return count to a high number, the nozzle will become easily clogged when
printing for a long time because flushing is not performed over the capping unit.
<Example of spitting operation>
Setup item
Setting
Description
ReturnCount
1 time to <2 times> to 999
times
Set the spitting return count.
—
• [Enter] key: saves the setting and shifts to the previous
menu.
• [Cancel] key: cancels the setting and shifts to the previous
menu.
Spitting setting
Return Count setting
Operation
On
1 time
Performs the spitting operation on the capping unit on the
origin side every time the print head returns to the origin
position.
Spitting is not performed over the media.
On
5 times
Performs the spitting operation on the capping unit on the
origin side every five times the print head returns to the origin
position.
Spitting is not performed over the media.
On Media
1 time
Performs the spitting operation on the capping unit on the
origin side every time the print head returns to the origin
position.
Flushing is performed over the media every time the print
head shuttles back and forth.
On Media
5 times
Performs the spitting operation on the capping unit on the
origin side every five times the print head returns to the origin
position.
Flushing is performed over the media every time the print
head shuttles back and forth.
Off
—
Spitting is not performed on the capping unit or the media.
Содержание 54 Gen2
Страница 1: ......
Страница 2: ......
Страница 138: ...Handling the printer PrismJET 54 Gen2 OPERATION MANUAL 148 4 4 Operating from the operation panel...
Страница 205: ...PrismJET 54 Gen2 OPERATION MANUAL Maintenance 215 6 Maintenance This chapter describes daily maintenance of the product...
Страница 304: ...Appendix PrismJET 54 Gen2 OPERATION MANUAL 314 8 3 Options Supply list...
Страница 305: ......