SPARE PART LIST

ITEM NO  DESCRIPTION

412-2005  Transducer Standard, min 89 mm including measuring tip 10 mm

412-2214  Transducer Tip, Standard

412-2643  Adjusting sleeve, Standard, 12 mm

412-2794  Locking Ring, Standard, 12 mm

412-2893  Cable 7p/5p DIN, 3,6 meter

412-2897  Cable 7p/5p DIN, 7 meter

412-2899  Magnet to be Attached to cable

423-3005  Transducer Small, min 60 mm, including measuring tip 7 mm

423-3637  Adjusting sleeve, small 10 mm

423-3641  Locking Ring, Small, 10 mm

434-4005  Transducer W, min 100 mm, including measuring tip 10 mm

434-4758  Transducer Tip, 17 mm

458-5000  Extension Bar Set: 2x160 mm, 1x80, 40, 20, 10 mm, 10 mm measuring tip

458-5107  Extension Bar, 10 mm

458-5160  Extension Bar, 160 mm

458-5205  Extension Bar, 20 mm

458-5402  Extension Bar, 40 mm

458-5809  Extension Bar, 80 mm

458-6000  Spare Tips Set: 

 

Transducer Tip Standard & 17 mm, 

 

Measuring Tip Standard & 14 mm

458-6074  Measuring Tip, small, 7 mm

458-6106  Measuring Tip, Standard, 10 mm

458-6123  Measuring Tip, 14 mm

365-6022  Battery Li-Ion with 3 wires connector

501-1990   Battery Li-Ion with 2 wires connector

501-1992  Charger for Li-Ion battery

12-2903-A Prisma DI Plastic Case, Black 300x265x140 mm

Содержание DI-5 Series

Страница 1: ...M A N U A L I N S T R U M E N T DI 5...

Страница 2: ...Battery Charge Port Transducer port Transducer Tip Locking Ring Measuring Tip Extension Bar 10 mm Extension Bar 20 mm Extension Bar 40 mm Extension Bar 80 mm Extension Bar 160 mm INSTRUMENT OVERVIEW...

Страница 3: ...on 6 Fit the transducer between the webs in the punch marks Adjust the screw ring to a reading close to zero and lock it with the locking ring 7 Push ZERO button 8 Rotate crankshaft and check deflecti...

Страница 4: ...arting with the measurement SAFETY INSTRUCTIONS Be careful with tools that may cause short circuit at the battery charge port Make sure to use only the original charger supplied with the Prisma DI 5 T...

Страница 5: ...er 5 if mounted 6 Unscrew the tip 6 from the core 7 and mount the new transducer tip 7 Remount in opposite order 2 3 5 6 7 1 4 MAINTENANCE The calibration certificate supplied with the Prisma DI 5 is...

Страница 6: ...Transducer W min 100 mm including measuring tip 10 mm 434 4758 Transducer Tip 17 mm 458 5000 Extension Bar Set 2x160 mm 1x80 40 20 10 mm 10 mm measuring tip 458 5107 Extension Bar 10 mm 458 5160 Exte...

Страница 7: ...and Recycling of Prisma DI 5 The metal parts to be recycled as metals The electronic parts to be recycled as electronics The plastic case bag to be recycled as plastic The Lithium Ion battery to be r...

Страница 8: ...ner is in the cylinder top Using the Prisma DI Ovality Kit together with Prisma DI 5C and kit you do have an outstanding funktion to load all your measurements into the PC software and print out graph...

Отзывы: