HOW TO USE THE INSTRUMENT

1.  Ensure that the cable is properly connected.
2.  Select the applicable extension bar(s).

 

 

Don´t fit the transducer yet.

3.  Push POWER button and hold shortly.

  

Check the battery level when battery symbol show up.

  

If battery level is low charge the battery with the 

 

enclosed charger.

  

Follow the Charger manual.

 

Note!

  

 

Use only the charger delivered with instrument.

4.  Push LIGHT button if needed.

  

The backlight LEDs will light for 15 sec after  

 

every button push.

5.  Push RESET button
6.  Fit the transducer between the webs in  

 

the punch marks.

   

 

Adjust the screw ring to a reading close  

 

to zero and lock it with the locking ring.

7.  Push ZERO button.
8.  Rotate crankshaft and check deflection by normal procedure. 
9.  Note the results,

  and  keep  them  to  compare  with  the  next  measurements.                                                                                                                 

10.  Remove the transducer by pressing it to one side.

 

Note!

 

 

It is normally unnecessary to unlock the adjuster.

11.  Fit the transducer into the next crank web position.
12.  Repeat the procedure from step 6.

NOTE 1

If the DI-5 is not used for 

a long time, then it´s 

necessary to charge the 

battery at least 

once a year.

NOTE 2

Don’t use the 

charger as a 

power supply. 

It’s only for 

charging the 

Li-Ion battery.

Содержание DI-5 Series

Страница 1: ...M A N U A L I N S T R U M E N T DI 5...

Страница 2: ...Battery Charge Port Transducer port Transducer Tip Locking Ring Measuring Tip Extension Bar 10 mm Extension Bar 20 mm Extension Bar 40 mm Extension Bar 80 mm Extension Bar 160 mm INSTRUMENT OVERVIEW...

Страница 3: ...on 6 Fit the transducer between the webs in the punch marks Adjust the screw ring to a reading close to zero and lock it with the locking ring 7 Push ZERO button 8 Rotate crankshaft and check deflecti...

Страница 4: ...arting with the measurement SAFETY INSTRUCTIONS Be careful with tools that may cause short circuit at the battery charge port Make sure to use only the original charger supplied with the Prisma DI 5 T...

Страница 5: ...er 5 if mounted 6 Unscrew the tip 6 from the core 7 and mount the new transducer tip 7 Remount in opposite order 2 3 5 6 7 1 4 MAINTENANCE The calibration certificate supplied with the Prisma DI 5 is...

Страница 6: ...Transducer W min 100 mm including measuring tip 10 mm 434 4758 Transducer Tip 17 mm 458 5000 Extension Bar Set 2x160 mm 1x80 40 20 10 mm 10 mm measuring tip 458 5107 Extension Bar 10 mm 458 5160 Exte...

Страница 7: ...and Recycling of Prisma DI 5 The metal parts to be recycled as metals The electronic parts to be recycled as electronics The plastic case bag to be recycled as plastic The Lithium Ion battery to be r...

Страница 8: ...ner is in the cylinder top Using the Prisma DI Ovality Kit together with Prisma DI 5C and kit you do have an outstanding funktion to load all your measurements into the PC software and print out graph...

Отзывы: