4–98
Configuration Menus
Auto Switching Menu
Auto Switching
Parallel Hotport
C/T Hotport
Serial Hotport
Port Type
Centronics*
Data Products
IEEE 1284
Disable
Trickle Time
1/4 Sec*
1/2 Sec
1 Sec
2 Sec
4 Sec
8 Sec
16 Sec
Off
Timeout
10 Sec*
1 – 60
Report Status
Disable*
Enable
* = Factory default
Port Type
RS 232*
RS 422
Disable
Trickle Time
1/4 Sec*
1/2 Sec
1 Sec
2 Sec
4 Sec
8 Sec
16 Sec
Off
Timeout
10 Sec*
1 – 60
Report Status
Disable*
Enable
Port Type
Twinax*
Coax
Disable
Timeout
10 Sec*
1 – 60
Report Status
Disable*
Enable
Auto Switching
Gives the printer the ability to handle multiple data streams simultaneously. It
allows the printer to service hosts attached to the serial, parallel, coax and twinax
ports as if they were the only interface connected.
Port Type
Selects the type of parallel interface.
Trickle Time
This functionality prevents an attached host from timing out. In order to support
this feature, the port has to be able to accept data from the host and store it for
future use. The selected value is the time that the printer waits before getting the
next byte of data from host. Set the value to be less than the host time out value,
but the value should not be too much shorter so the printer fills up its buffer too
fast. This function is not applicable for C/T hotport.
Содержание P5005A
Страница 1: ......
Страница 7: ...Contents iv...
Страница 11: ...1 4 Introduction...
Страница 175: ...4 122 Configuration Menus...
Страница 193: ...5 18 Interfaces...
Страница 215: ...A 10 Printer Specifications...
Страница 216: ...Demand Printing B 1 B Demand Printing Overview B 2 Simple Tear B 3 Form Saver Mode B 5...
Страница 223: ...C 2 ASCII Character Set...