5–5
Interfaces
Dataproducts Parallel Interface
Table 5–2. Dataproducts Parallel Interface Connector Pin Assignments
(with a 50-pin AMP HDH-20 Data Cable Connector)
Input Signals
Output Signals
Miscellaneous
Signal
Pin
Signal
Pin
Signal
Pin
DATA LINE 1
19
Return
3
READY
22
Return
6
CABLE VERIFY
45, 46
DATA LINE 2
20
Return
4
ONLINE
21
Return
5
GROUND
39
DATA LINE 3
1
Return
2
DEMAND/DATA REQUEST
23
Return
7
DATA LINE 4
41
Return
40
PARITY ERROR
27
Return
11
DATA LINE 5
34
Return
18
DATA LINE 6
43
Return
42
DATA LINE 7
36
Return
35
DATA LINE 8
28
Return
44
DATA STROBE
38
Return
37
PAPER INSTRUCTION 30
Return
14
BUFFER CLEAR
31
Return
15
Note: Pins not listed are not connected.
The length of the data cable from the host computer to the printer must not
exceed 40 feet (12 meters).