CTD & CTDE
Vertical Contact Toasters
12
301-500rev
E
-EN
Troubleshooting
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equipment should be
performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are
required. Use extreme care during electrical circuit texts. Live circuits will be exposed.
WARNING
BURN/ELECTRICAL SHOCK HAZARD! Platen is HOT and can cause severe burns or severe shock.
Keep hands and objects out of the toaster unit! Failure to exercise caution may result in serious injury!
Turn the unit off, unplug it and let it cool down completely before touching or working on internal apparatus. The plug removed
from the outlet shall remain clearly visible to the operator during the maintenance procedure.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Unit has no power
Unit unplugged
Plug unit in.
Breaker tripped
Reset breaker.
Loose connection on power switch
Call Tech Support 1-800-722-7853
Inoperable power switch
Unit will not heat up
Loose connection on platen
Call Tech Support 1-800-722-7853
Open platen
Loose connection to the main control board
Inoperable main control board
Inoperable
TRIAC
Unit heats up, but the conveyors
do not run
The conveyor door is ajar
Verify that the door is closed.
Inoperable motor
Call Tech Support 1-800-722-7853
Stripped drive gear
Stripped conveyor gear
Jammed conveyor assembly
Not toasting properly (under- or
over-done)
Inoperable
RTD
-probe
Call
Tech Support 1-
8
00-722-7853
Improper set point
Adjust set point in programming (see
Setting
Adjustments
section).
Improper compression
Adjust compression (see
Setting Adjustments
section).
Torn or soiled release sheet
Clean or replace release sheet.
Bad platen
Call Tech Support 1-800-722-7853
Jumpy
or blank
display
Improper ground
Call Tech Support 1-800-722-7853
Inoperable display
Inoperable main control board
Loose wiring harness
E01 error code visible on display
Relay shorted or open
Call Tech Support 1-800-722-7853
E02 error code visible on display
Conveyor 1 either jammed or not working
Call Tech Support 1-800-722-7853
E03 error code visible on display
Conveyor 2 either jammed or not working
Call Tech Support 1-800-722-7853
E05 error code visible on display
Set point temperature not reached in
expected time
Call Tech Support 1-800-722-7853
E06 error code visible on display
Software files on USB not valid
Call Tech Support 1-800-722-7853
E07 error code visible on display
Transferred software files on external Flash
not valid
Call Tech Support 1-800-722-7853
E08 error code visible on display
Temperature sensor open or shorted
Call Tech Support 1-800-722-7853
E09 error code visible on display
Current platen temperature 20
F higher
than set point temperature
Call Tech Support 1-800-722-7853
E10 error code visible on display
Current platen temperature 20
F lower than
set point temperature
Call Tech Support 1-800-722-7853
N1 notification visible on display
Reminder to clean
Clean unit and delete message.
NOTE: For all other problems, call approved local service agent.
Printed in USA
5/1/2022
Содержание CTD
Страница 2: ...CTD CTDE Vertical Contact Toasters Printed in USA 5 1 2022 2 301 500revE EN ...
Страница 13: ...CTD CTDE Vertical Contact Toasters 13 Installing the Silicone Belt Printed in USA 5 1 2022 301 500revE EN ...
Страница 14: ...CTD CTDE Vertical Contact Toasters 14 Removing the Silicone Belt Printed in USA 5 1 2022 301 500revE EN ...
Страница 19: ...CTD CTDE Vertical Contact Toasters 19 301 500revE EN Exploded Views Printed in USA 5 1 2022 ...
Страница 20: ...CTD CTDE Vertical Contact Toasters 20 301 500revE EN Exploded Views continued Printed in USA 5 1 2022 ...
Страница 21: ...CTD CTDE Vertical Contact Toasters 21 301 500revE EN Exploded Views continued Printed in USA 5 1 2022 ...
Страница 22: ...22 301 500revE EN Exploded Views continued Printed in USA 5 1 2022 CTD CTDE Vertical Contact Toasters ...
Страница 23: ...23 301 500revE EN Wiring Diagram Printed in USA 5 1 2022 CTD CTDE Vertical Contact Toasters ...