background image

CTD & CTDE 

Vertical Contact Toasters 

12 

301-500rev

E

-EN

Troubleshooting 

WARNING 

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equipment should be 

performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are 

required. Use extreme care during electrical circuit texts. Live circuits will be exposed. 

WARNING 

BURN/ELECTRICAL SHOCK HAZARD! Platen is HOT and can cause severe burns or severe shock. 

Keep hands and objects out of the toaster unit! Failure to exercise caution may result in serious injury! 

Turn the unit off, unplug it and let it cool down completely before touching or working on internal apparatus. The plug removed 

from the outlet shall remain clearly visible to the operator during the maintenance procedure. 

PROBLEM 

POSSIBLE CAUSE 

SOLUTION 

Unit has no power 

Unit unplugged 

Plug unit in. 

Breaker tripped 

Reset breaker. 

Loose connection on power switch 

Call Tech Support 1-800-722-7853 

Inoperable power switch 

Unit will not heat up 

Loose connection on platen 

Call Tech Support 1-800-722-7853 

Open platen 

Loose connection to the main control board 

Inoperable main control board 

Inoperable 

TRIAC 

Unit heats up, but the conveyors 
do not run 

The conveyor door is ajar 

Verify that the door is closed. 

Inoperable motor 

Call Tech Support 1-800-722-7853 

Stripped drive gear 

Stripped conveyor gear 

Jammed conveyor assembly 

Not toasting properly (under- or 
over-done) 

Inoperable 

RTD

-probe 

Call 

Tech Support 1-

8

00-722-7853 

Improper set point 

Adjust set point in programming (see 

Setting 

Adjustments 

section). 

Improper compression 

Adjust compression (see 

Setting Adjustments 

section). 

Torn or soiled release sheet 

Clean or replace release sheet. 

Bad platen 

Call Tech Support 1-800-722-7853 

Jumpy 

or blank 

display 

Improper ground 

Call Tech Support 1-800-722-7853 

Inoperable display 

Inoperable main control board 

Loose wiring harness 

E01 error code visible on display 

Relay shorted or open 

Call Tech Support 1-800-722-7853 

E02 error code visible on display 

Conveyor 1 either jammed or not working 

Call Tech Support 1-800-722-7853 

E03 error code visible on display 

Conveyor 2 either jammed or not working 

Call Tech Support 1-800-722-7853 

E05 error code visible on display 

Set point temperature not reached in 
expected time 

Call Tech Support 1-800-722-7853 

E06 error code visible on display 

Software files on USB not valid 

Call Tech Support 1-800-722-7853 

E07 error code visible on display 

Transferred software files on external Flash 
not valid 

Call Tech Support 1-800-722-7853 

E08 error code visible on display 

Temperature sensor open or shorted 

Call Tech Support 1-800-722-7853 

E09 error code visible on display 

Current platen temperature 20

F higher 

than set point temperature 

Call Tech Support 1-800-722-7853 

E10 error code visible on display 

Current platen temperature 20

F lower than 

set point temperature 

Call Tech Support 1-800-722-7853 

N1 notification visible on display 

Reminder to clean 

Clean unit and delete message. 

NOTE: For all other problems, call approved local service agent. 

Printed in USA 

5/1/2022

Содержание CTD

Страница 1: ...ropping tampering with or altering electrical components or improper cleaning is not covered Equipment damaged in shipment by fire flood or an act of God is not covered Damage to non stick coated surfaces is not covered by this warranty 355 East Kehoe Blvd Carol Stream IL 60188 USA Telephone 630 462 8800 Toll Free 1 800 PCASTLE Fax 630 462 1460 www princecastle com TABLE OF CONTENTS Safety Informa...

Страница 2: ...CTD CTDE Vertical Contact Toasters Printed in USA 5 1 2022 2 301 500revE EN ...

Страница 3: ... 1650 2000 6 87 9 10 CTDE W Toaster Wire Belt 208 240 50 60 2440 3250 9 40 14 40 CTDE M Toaster Metal Belt 208 240 50 60 2440 3250 9 40 14 40 CTDE S Toaster Silicone Belt 208 240 50 60 2440 3250 9 40 14 40 CTDE W CE Toaster Wire Belt 220 240 50 60 3000 12 5 13 64 CTDE M CE Toaster Metal Belt 220 240 50 60 3000 12 5 13 64 CTDE S CE Toaster Silicone Belt 220 240 50 60 3000 12 5 13 64 XXX XX AX Auxil...

Страница 4: ...n the outside of the toaster Using a clean cloth with lukewarm soap and water wipe the outside of the entire toaster Wipe again with a dry clean and sanitized cloth 9 Install release sheet Hang the folded PTFE release sheet straddling the platen The tan material will need to fully cover both sides of the heating element This is important in preventing the bun from sticking Moisture coming out of t...

Страница 5: ...point or the Minus symbol to decrease the set point C Press the check mark to accept the setting The Warm Up screen reappears and warm up continues NOTE If you don t want to accept the change you can wait for the screen to time out or you can press the back arrow 3 WARNING BURN ELECTRICAL SHOCK HAZARD Platen area is HOT and can cause severe burns or severe shock Keep hands and objects out of the t...

Страница 6: ...nning A Press the Recipes icon on the Run Home screen The Recipes screen will appear B Press the Left arrow or Right arrow to change the recipe C Press the check mark to accept the change NOTE If you don t want to accept the change you can press the Return arrow 3 Change the Temperature set point From the Run Home screen you can change the Temperature set point A Press the thermometer icon on the ...

Страница 7: ...the Plus symbol to increase the setting or the Minus symbol to decrease the setting C Press the check mark to accept the setting NOTE If you don t want to accept the change you can press the Return arrow 6 Save the current settings as the current recipe If you have adjusted the current settings and you want to save the settings to the current recipe you can do this on the Recipe screen A Press the...

Страница 8: ...is the brightest and 1 is the dimmest D Press the Plus symbol to increase the setting or the Minus symbol to decrease the setting E Press the check mark to accept the setting NOTE If you don t want to accept the change you can press the Return arrow 2 Access statistics From the Run Home screen you can access statistics if you have a PIN A Press the Service icon on Run Home screen The Access Settin...

Страница 9: ...resentative to access this feature A Press the Settings icon on Run Home screen The Access Settings Service screen will appear B Type the Service PIN code and press the check mark The Settings screen will appear C Press the Temperature Units icon The Temperature Units screen will appear with the current setting selected D Press the other setting E Press the check mark to accept the setting NOTE If...

Страница 10: ...nplug it and follow the Cool Down procedure before touching or working on internal apparatus WARNING If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person to avoid a hazard CAUTION Do not immerse toaster in water Do not clean with a water hose or jet spray Do not use abrasive cleaners pads or tools on the platen or the release sheet F...

Страница 11: ... the entire surface with a clean cloth dampened with sanitizer solution Dampen a clean cloth with lukewarm soap and water Wipe the inside of doors and bun infeed Wipe the inside of the doors and bun infeed again with a fresh clean sanitized cloth CAUTION Do not use abrasive cleaners or pads on the conveyor surface 9 Close the conveyor doors 10 Reinstall the bun infeed 11 Clean outside of the toast...

Страница 12: ...er or over done Inoperable RTD probe Call Tech Support 1 800 722 7853 Improper set point Adjust set point in programming see Setting Adjustments section Improper compression Adjust compression see Setting Adjustments section Torn or soiled release sheet Clean or replace release sheet Bad platen Call Tech Support 1 800 722 7853 Jumpy or blank display Improper ground Call Tech Support 1 800 722 7853...

Страница 13: ...CTD CTDE Vertical Contact Toasters 13 Installing the Silicone Belt Printed in USA 5 1 2022 301 500revE EN ...

Страница 14: ...CTD CTDE Vertical Contact Toasters 14 Removing the Silicone Belt Printed in USA 5 1 2022 301 500revE EN ...

Страница 15: ...CTD CTDE Vertical Contact Toasters 15 301 500revE EN Accessories 511 142 Butter Wheel CTD 511 141 Butter Wheel CTDE Butter Wheel Hanging Points Printed in USA 5 1 2022 ...

Страница 16: ... Bushing 5 6 7 8 525 127S Door Cut Off Switch 301 023S Rack 301 044S Indexer 301 022S Gear 9 10 11 12 301 087S High Limit Probe Clip 301 062S CTD 302 030S CTDE Release Sheet 78 233S Switch Rocker DPST IP65 16A 301 049S Detent Mechanism Bushing 13 14 15 16 301 025S Compression Adjust Sleeve Bearing 70 081S Indicating Knob 301 074S Display Module 7500 006S LCD Adapter Printed in USA 5 1 2022 ...

Страница 17: ...21 22 23 24 302 034S EL240A30 05 7500 007S Control Board 301 014S CTD 302 015S CTDE Wire Conveyor Belt Install Tool 301 013S CTD 302 016S CTDE Tracking Conveyor Belt Install Tool 25 26 27 28 301 137S CTD 302 050S CTDE Silicone Belt 301 110S Conveyor Sprocket 301 117S Electric Thermostat 301 047S Detent Mechanism Spring 29 30 31 32 66 072S Cord Strain Relief Elbow 72 519S U S L6 20P 72 525S CEE7 7 ...

Страница 18: ... 034S Spring Chain Tensioner L Not Shown 40 88 828S Filter EMI 41 301 090S High Limit Cable CTD 302 041S High Limit Cable CTDE 42 301 091S Harness RTD 43 301 092S Harness LCD 44 301 093S Harness SSR 45 301 094S Power Harness AC 46 301 095S Power Harness DC 47 301 097S Wire Neutral 48 301 098S Harness Door Switch 46 301 099S Harness Auxiliary Heater 50 302 036S Harness Auxiliary Heater Printed in U...

Страница 19: ...CTD CTDE Vertical Contact Toasters 19 301 500revE EN Exploded Views Printed in USA 5 1 2022 ...

Страница 20: ...CTD CTDE Vertical Contact Toasters 20 301 500revE EN Exploded Views continued Printed in USA 5 1 2022 ...

Страница 21: ...CTD CTDE Vertical Contact Toasters 21 301 500revE EN Exploded Views continued Printed in USA 5 1 2022 ...

Страница 22: ...22 301 500revE EN Exploded Views continued Printed in USA 5 1 2022 CTD CTDE Vertical Contact Toasters ...

Страница 23: ...23 301 500revE EN Wiring Diagram Printed in USA 5 1 2022 CTD CTDE Vertical Contact Toasters ...

Отзывы: