247-500revH-EN
9
Printed in USA 03/10 © 2010
Toaster Grills
Models 247-ACC & 248-BCC
View/Calibrate Platen Temperature
Important!
Do NOT perform this procedure until the Toaster Grill has been
on for at least 45 mins. and the temperature has stabilized. Do
NOT use the Toaster Grill during the first 45 minutes.
Temperature can only be adjusted ±10°C (±18°F) during
calibration.
Important!
If the temperature reading from the external temperature port is
greater than ±3°C (±5°F) compared to the Toaster Grill
temperature display, proceed with the following. If temperature
reading is within ±3°C (±5°F), the Toaster Grill is functioning
properly and does not need calibration.
Upper Platen (248-BCC Models Only)
A. Plug an external temperature meter into the external
port (Type K mini-jack) of the heater platen.
B. Using the external temperature meter as a standard,
adjust the Toaster Grill’s temperature display to match
the meter’s temperature display by the following
procedure.
1
NOTE: Yellow Type K Thermocouple mini-jack temperature
ports are located on the back of the 248-BCC Model, behind
each of the two platens. (See Figure 14.)
Figure 14
Upper External
Lower External
A. To view and/or calibrate the platen temperature, press
and hold the
LOGO
button.
B. Immediately press the
UP
button to view the Upper
Platen temperature on 248-BCC Models.
C. Release both buttons. (See
Figure 15
.)
The display shows the Upper Platen’s temperature.
After 3 seconds, the display returns to showing the
currently selected product.
2
Figure 15
Press LOGO Button
and UP Arrow
Display Shows the
Upper Platen Temperature
(248-BCC Only)