16
70276001
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
15. WATER IN STEAM LINE - STEAM MODELS
POSSIBLE CAUSE
TO CORRECT
Incorrect installation of steam piping.
• Refer to Installation Manual for steam requirements.
Trap functioning improperly.
• Check trap for size and capacity. If trap is dirty or
sluggish, clean thoroughly or replace. Check return line
for high back pressure. Check trap for proper installation.
Refer to Installation Manual for requirements.