12
70276001
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
6. BURNER IGNITES AND GOES OUT REPEATEDLY
7. BURNER SHUTS OFF PREMATURELY
POSSIBLE CAUSE
TO CORRECT
Insufficient gas pressure.
• Check gas supply and pressure. Low flame will not
maintain sensor conductivity.
Burner ports plugged.
• Check burner tubes for build-up.
Improper or inadequate exhaust system or make-up
air
• Refer to Installation Manual for exhaust and make-up air
requirements.
Inoperative high limit or cabinet limit thermostat.
• Test thermostat and replace if inoperative.
Improper orifices.
• Tumbler is equipped for type of gas specified on serial
plate. If orifices are different from that specified on serial
plate, obtain and install proper orifices.
Improper flame recognition circuit.
• Replace high voltage lead.
• Replace ignitor
• Replace ignition control module.
POSSIBLE CAUSE
TO CORRECT
Improper or inadequate exhaust and/or make-up air
system.
• Refer to Installation Manual for exhaust and make-up air
requirements.
Insufficient gas supply.
• Open partially closed gas shut-off valve or correct low
pressure.
Tumbler not properly equipped for type of gas used
or altitude.
• Tumbler is equipped for type of gas specified on serial
plate. If not properly equipped for gas type and altitude,
obtain and install correct components.
Improperly adjusted burner flame.
• Refer to Adjustment Section in this manual for burner
flame adjustment.
Cycling off on high limit thermostat.
Broken, loose or incorrect wiring.
• Refer to wiring diagram located on back of tumbler or in
literature packet.
Improper fan rotation.
• May be due to improper wiring resulting in low airflow.
Refer to Installation Manual.
Inoperative gas valve coils.
• Test coils and replace if inoperative.
Содержание D55
Страница 1: ...D55 SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 10 03 70276001 ...
Страница 2: ......
Страница 10: ...8 70276001 Section 2 Introduction Notes ...
Страница 24: ...22 70276001 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 54: ...52 70276001 Section 5 Service Procedures Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 80: ...78 70276001 Section 7 Wiring Schematics Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 81: ......
Страница 82: ......