7.Troubleshooting 
7.1

 

The pump does not run: 

 

Check the red lamp (LED) responding to the pump, on the PC card typ.1098 or 0599, 
which  is next to the black micro relay of 30A. If the red lamp is on check the  fuse 6 
Amber responding to the pump on the PC card typ 1098 or 0599. 

 

Check if the voltage of the power supplied to the pump is 230V. 

 

Check if the pump is stuck off due to corrosion or salts.This usually happens when the 
pump  is  out  of  work  for  a  long  period  of  time. 
Shooting  :  Turn  the  Pivot  of  the  pump  by  putting  a 
screwdriver  though  the  hole  of  the  backside  of  the 
machine which leads to the pump.  

 

Check if the pump is blown-off. Replace it.  

 

7.2

 

The water is not heated while the green lamp 1(steam) lights on. 

 

Check  the  red  lamp  (LED)  which  is  used  for  the  heating  micro  relay  on  the  PC  card 
typ.1098 or 0599 No 36. 

 

If it is on, check the fuse 1 Amber which is used for the heating micro relay on the PC 
card typ.1098 or 0599 No 36 

 

Check  the    micro  relay  2x10  Amber  which  is  used  for  the  heating    on  the  PC  card 
typ.1098 or 0599 No 36. 

 

If the red lamp (LED) responding to the heating micro relay is off check the pressostat 
No 14  (symbol PS on the wiring diagram)  

 

Check the heating relay  3 x 25A , R1 (symbol on the wiring diagram) 

 

Check the overheating system

 

 7.3 The boiler is overheated. The overheating lamp (No 54) is on. 

 

Wait for a while, until the steam generator brings the temperature down.  

 

Unscrew the black knob towards left(No24). 

 

Inside, there is a small black buttom.(RESET)Press it. The overheating lamp is of. 

The  steam genarator is then ready to refunction. In case  that even after the RESET proce- 
dure  the  steam  generator  does  not  function,  please    ask  immediately    for  technical 
assistance. 
Shooting
:Clean  up  the  steam  generator  and  the  electrodes  from  salts  and  replace  the 
electrodes  if  necessary.Check  the  water’s  level  control  system.Do  the  test  for  the  good 
operation of the machine.

       

 

 

7.4

 

The steam iron is not heated while the iron green lamp (on the keyboard) lights 
on.
 

 

Check the red lamp (LED) responding to the iron on the PC card typ 1098 or 0599. If it 
is on check the fuse 6 Amber responding to the iron on the PC card typ 1098 or 0599 

 

Check the micro relay 2x10 Amber responding to the iron on the PC card 1098 or 0599 

 

Check the socket (PF1 or PF2 on the wiring diagram) where the iron is plugged.  

 

Check the iron itself.

    

 

 

If the iron is heated normally but it does not blow steam check coil No 31 (12W/230V) of 

the solenoid steam valves (V1, V2 on the wiring diagram) 
 

7.5

 

The boiler is overfilled and the iron blows steam & water  

 

Check the electrodes No 46,47,48 :clean or replace them. 

 

Check the solenoid water valve No18 : clean or replace it.  

 

Check if the water’s level control system on the PC card typ.1098 is running normally.  

Содержание Vapormat

Страница 1: ...IRONING PRESSING MACHINERIES FUSING PRESSES Instruction Manual Vapormat CE...

Страница 2: ...r 9 6 Maintenance Testing 9 6 1 Maintenance 9 6 2 Test the good operation of the machine 9 7 Troubleshooting 10 7 1 The pump does not run 10 7 2 The water is not heated while the steam lamp lights on...

Страница 3: ...this operating manual You may not copy reproduce or translate this operating manual or parts of it to another language without prior written consent of Primula SA Any information in this manual may be...

Страница 4: ...The serial number plate has been placed in a visible place on the steam generator and is made from fadeless material Amongst others the Serial Number plate displays the following Amongst others the Se...

Страница 5: ...5 L thickness 7 1mm The water drops glide down to the bottom of the boiler Outside and inside welding of boiler to avoid oxidation Double steam outlet for 2 Irons which keeps the steam dry Water inle...

Страница 6: ...ccordance with the current instruction manual and only with the accessories that are provided or that are intended for this specific Steam Generator The manufacturer is not liable for any damages resu...

Страница 7: ...han the above requirements it is recommended to use ANTISCAL The lime contained in the water may be placed in the boiler and on the heating elements will cause faults The use of ANTISCAL prevents depo...

Страница 8: ...e for steam preparation is 9 11 min The manometer should reach 3 5 bars The machine is ready to work Press the iron s buttons on the control keyboard Press only one button if the requested produced st...

Страница 9: ...13 6 1 Maintenance Keep the machine as clean as possible Clean the inside of the machine by compressed air at least 2 times per year Depending on the quality of the water Clean periodically the electr...

Страница 10: ...stem 7 3 The boiler is overheated The overheating lamp No 54 is on Wait for a while until the steam generator brings the temperature down Unscrew the black knob towards left No24 Inside there is a sma...

Страница 11: ...periods steam draining is appeared in the feeder vessel No 41 Check the one way valve No 16 Clean or replace it paying attention on putting it back correctly 7 7Safety valve Check the pressostat No 1...

Страница 12: ...cut off operation Replace the PC board 4 Water Error The red light is on 35sec Problem at the water Check the pump No 2 after the starting feeding or its circulation is faulty or stuck in the machine...

Страница 13: ...Instruction Manual VARORMAT 13 Images of spare parts...

Страница 14: ...Pressostat s coil new model since 2019 16 303 03 016 One way valve 1 2 17 303 03 017 Corner 1 2 Male Female 18 303 06 059 Corner 1 4 Male female 19 303 03 019 Condensate s pipe 20 306 11 051 Control l...

Страница 15: ...p 10 16 46 193 03 046 Electrode No 1 47 193 03 047 Electrode No 2 48 193 03 048 Electrode No 3 49 303 03 049 Grounded terminal block 6 poles 50 193 06 042 Pipe of safety valve 51 303 03 051 Water inle...

Страница 16: ...Instruction Manual VARORMAT 16 Wiring diagram...

Страница 17: ...2 E V Solenoid water valve V2 Solenoid steam valve No 1 V3 Solenoid steam valve No 2 PM Water pump 0 5HP Water pump 0 7HP E1 Water level electrode max E2 Water level electrode min E3 Heating protecti...

Страница 18: ...ealer you have purchased the machine from or us directly at 14th km Thessaloniki Kilkis 57200 Liti Thessaloniki Greece Tel 30 23940 71 215 Fax 30 23940 71 438 E mail info primula gr All specifications...

Отзывы: