Instruction Manual VARORMAT
12
8.
Control keyboard indications
Symbol
Indication
Message
What to do
1-"steam ON"
The green light is on.
The procedure of water
-
heating starts. When the
green light is off (in 15-
18’ from 10
o
C) steam is
ready.
2-"pump ON"
The green light is on.
The pump feeds water to
-
the boiler normally.
3-"Level Error"
The red light is on.
Problem at the water
-Clean or replace
level control system.
electrodes No 46,47,48.
Automatic interruption
-Check if the electrodes
of the machine
wiring has been cut off.
operation.
-Replace the PC board
4-"Water Error" The red light is on 35sec
Problem at
the water -Check the pump No 2
after the starting.
feeding or its circulation
is faulty or stuck.
in the machine.
-Check if the pump's
Automatic
interruption pressure is low.
of
the
machine -Clean pipes No 9 & 20
operation.
from salts & rubbish
- Replace the solenoid
water valve No 18.
- Check if feedvessel No
41 is empty of water.
Button "ON"
The green light is on.
Machine is on function.
-
The green light is off.
Machine is out of
function.
Iron’s buttons
1.The green light is on, to
1.The machine supplies
the left or the right
steam to 1 iron.
button.
-
2.The machine supplies
2.The green light is on, at
steam to 2 irons.
both buttons.