Clock/Timer Model
A
B
C
D
E
F
G
H
4” 4-digit
8.0”
18.0”
3.0”
14”
0.4 – 0.9”
N/A
12.0”
4.0”
4” 6-digit
8.0”
23.3”
3.0”
14”
0.4 – 0.9”
N/A
12.0”
4.0”
2.5” 6-digit Flush Mount
6.3”
17.0”
0.3”
N/A
0.5 – 1.0”
N/A
N/A
N/A
4° bracket (2.5”)
4.3”
8.8”
N/A
N/A
N/A
N/A
8.0”
2.5”
4° bracket (4”)
7.8”
17.8”
N/A
N/A
N/A
N/A
12.0”
4.0”
18° bracket (2.5”)
4.3”
10.6”
N/A
N/A
N/A
N/A
9.5”
2.5”
120VAC Wiring
Primex Classic Digital Clocks/Timers are shipped from the factory with either a plug or pigtail for permanent installation.
NOTE
Pigtail installation requires a 120V~ power line in a junction box installed by a licensed electrician. Leave a minimum of 6
in. (15 cm) of cord inside the junction box.
24VAC Wiring Guidelines
Primex Digital Clocks/Timers operate at a maximum current draw of 700mA (24VAC) and operate over a range of 20 - 26VAC.
For installations where 24VAC wiring exists - the gauge/length of the wire and rating for the supply transformer should be
verified to ensure adequate current supply and voltage for all connected devices.
For new installations - the supply wire gauge should be determined to ensure acceptable voltage drop based on installed length
from the supply transformer to most distant clock to ensure minimum voltage (20VAC) is assured.
Follow all National and Local Building Codes when installing clocks.
1. Be sure the 24VAC wiring is routed through the cable hole in the rear of the clock.
2. If a back plate is used, feed the 24VAC wiring harness through the back plate and attach it to the clock.
3. Hang the clock/timer vertically on one of the mounting screws.
4. Connect the 24VAC wiring harness. Use two wire nuts, sized appropriately for the gauge of wire, to secure the wires.
5. Finish hanging the clock/timer horizontally.