Code Blue Timer Operation
A Digital Code Blue Timer is a multifunction digital clock and timer that integrates with an existing code blue system to effectively
time each event.
When a code blue event is invoked a relay/pulse is sent from the code blue system to the timer, which triggers it to begin
counting up. If a code blue active event is in effect it will take priority and a previous task will run in the background until the
code blue event has stopped.
Code Blue Timer operation
l
Code Blue Timer function is triggered by the input of the wired connection to a code blue system and the use of the timer
switch control allows a user to halt a code blue count event.
l
Upon receiving a code blue system input, the code blue timer immediately enters code blue mode and starts counting up from
00:00:00. Upon reaching 99:59:59, the timer will beep for 3 seconds.
l
Code blue mode is indicated by the colon, dash and decimal points not being lit (in both viewing and counting modes).
l
Any other counting events remain operational in the background.
l
Time duration of the last code blue event is stored in memory, and can be viewed until a new code blue event is triggered.
l
A code blue count can be halted by pressing the STOP/START button. Pressing either DISPLAY or RESET is ignored while in
code blue mode.
l
Triggering of the code blue input while a current code blue event is counting is ignored.
l
In the event of a power outage, its internal memory maintains the correct time for a minimum of one hour without power;
requires a minimum one hour of charging time.
NOTE
If the code blue counter reaches 99:59:59 the counter will stop.
Timer Switch Control specifications
l
Designed to fit inside a single gang box (not supplied); typically 2 1⁄4 in. x 2 3⁄4 in. x 4 in. (11.45 cm x 6.99 cm x 10.15 cm).
l
Timer Switch Control can simultaneously activate two connected timers for even more accurate event management.
l
Timer Switch Control membrane switch and wall plate clean easily and resist common cleaners and disinfectants. Be sure to
test any cleaning solutions on a small area.
Code Blue Timer - Timer Switch Control operating specifications
The Timer Switch Control allows a use to halt a code blue event.
Pressing the
button...
Running Mode
Halted Mode
DISPLAY
EXIT
Ignored
Places display back in clock mode
Holding down DISPLAY for a minimum of four seconds shows the last code blue time.