12.2.2 Maximum permissible power density
To avoid damage to the optics, the maximum permissible power density of 250 kW/cm²
at the optics must not be exceeded.
The power density in kW/cm² is calculated according to the formula:
Formula 1: Calculation of the power density
To determine the maximum laser power, the result is weighted with a safety factor of 2.
The safety factor compensates the ratio of maximum to average power density.
Formula 2: Calculation of the permissible laser power depending on the beam diameter
The minimum permissible beam diameter in cm depending on the permissible power
density and laser power is calculated according to the formula:
Formula 3: Calculation of the minimum permissible beam diameter depending on the permissible
power density and the laser power
Example: With the maximum permissible power density of 250 kW/cm² at the optics
and a laser power of 4 kW, the minimum permissible beam diameter is calculated as
follows:
Fig. 12.3: Example calculation
Содержание Cube L1
Страница 1: ...Revision 03 EN 03 2021 35 0 6 Cube L1 LaserDiagnosticsSoftware LDS Cube App Original Instructions ...
Страница 2: ......
Страница 3: ...35 0 6 Cube L1 3 Revision 03 EN 03 2021 IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE USE ...
Страница 51: ...35 0 6 Cube L1 51 Revision 03 EN 03 2021 18 Declaration of conformity ...
Страница 55: ...35 0 6 Cube L1 55 Revision 03 EN 03 2021 ...
Страница 56: ...PRIMES GmbH Max Planck Str 2 64319 Pfungstadt Germany Tel 49 6157 9878 0 info primes de www primes de ...