![PRIMERGY TX300 S3 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/primergy/tx300-s3/tx300-s3_operating-manual_1601725084.webp)
84
Operating Manual
TX300
S3
Hot-plug PCI fault indication lights up
Troubleshooting and Tips
7.11
Hot-plug PCI fault indication lights up
MRL sensor was pressed without authorization
The locking bar for the relevant hot-plug PCI board bay was pressed without
authorization.
V
CAUTION!
Locking bar must not be operated unless the optical waveguide of the
corresponding PCI slot is not lit.
If there is a board in the PCI slot whose MRL sensor was illegally
pressed, an NMI is initiated (Blue Screen).
Ê
Press the ON/OFF button for longer than five seconds or remove the power
plug.
Ê
Reboot the server.
7.12
Hot-plug PCI voltage display does not light
up after the board has been replaced
Incorrect PCI board installed
Only PCI boards of the same type and with the same settings may be
exchanged.
If the boards do not match, the new board will not be commissioned: the enable
sequence is aborted after five seconds and the flashing power indicator extin-
guishes.
Ê
Check the new PCI board for type and settings (mode, speed).
Ê
Repeat the replacement process.
Содержание TX300 S3
Страница 1: ...PRIMERGY TX300 S3 Server Operating Manual Edition December 2006...
Страница 76: ......
Страница 86: ......
Страница 108: ......
Страница 124: ......