VL5 ™ WASH LUMINAIRE SERVICE MANUAL
To control the display scroll rate (slow it down or speed it up), set the thumbwheel switch to 040. After waiting a few
seconds, set the thumbwheel to 940 for the slowest scroll rate. The normal scroll rate is about 540. Scroll rate 040 is
too fast to read.
The following is a list of some standard error messages. If one of these messages appears, it will be displayed until
another test is selected.
+
[SoFT oPErATor] - the operator made a mistake, try again.
+
[SoFT SW] - the software made a mistake, try again.
+
[HArD SW] - the software failed due to previously unknown bug, report the bug.
+
[HArd HW] - something is broken, repair it.
Port Selection
Each Smart Repeater unit has six luminaire input/output ports that are labeled 1 through 6. One or all ports can be
selected for testing. The default setting is Port 1 only selected for test operations. To select ports for testing, set
thumbwheel switch to 51, and use the test parameter place on the thumbwheel to select the desired ports: 0 for all
ports, 1 through 6 for ports 1 through 6, respectively.
+
Port 1 only - 151
+
Port 2 only - 251
+
Port 3 only - 351
+
Port 4 only - 451
+
Port 5 only - 551
+
Port 6 only - 651
Only the Timer Test, RAM Test, Mechanics Tests, and Form and Function Test can be performed on all ports
simultaneously. The Encoder Tests and Data Loopback Test (external form) can be performed only on one port at a
time.
Programmed tests can be run on all ports simultaneously or on any one port. Port selection is not stored with the
program. So, a test can be programmed with only one port selected and the test can be run later with all ports
selected, or vice versa.
To operate the test software:
Step
1. Set Smart Repeater thumbwheel switch to 000 and connect luminaire to be tested to Port 1. (Up to six
luminaires may be connected, but at least one must be connected to start the test mode.)
Step
2. Apply power to Smart Repeater unit.
Step
3. Check LED display. Display should read [
Sr uP
], meaning "Smart Repeater Up."
Step
4. Check LED display. Display should read [
P1 F=n
], which means "Port 1 Form and Function Value=n," which
indicates luminaire is online at Port 1 (n=9 for VL6 luminaires). Luminaire will go through normal calibration,
except for its ending position.
Step
5. After calibration, press buttons above and below thumbwheel switch to enter desired test codes for testing
particular luminaire functions (refer to
on page 18 for a list of code numbers).
Содержание VARI LITE VL5
Страница 1: ...WWW PRG COM VARI LITE VL5 WASH LUMINAIRE SERVICE MANUAL...
Страница 10: ...VIII VL5 WASH LUMINAIRE SERVICE MANUAL Notes...
Страница 13: ...1 DESCRIPTION FEATURES MAJOR COMPONENTS PRINCIPLES OF OPERATION...
Страница 22: ...12 VL5 WASH LUMINAIRE SERVICE MANUAL Notes...
Страница 23: ...2 MAINTENANCE EQUIPMENT HANDLING TESTING MAINTENANCE PROCEDURES SERVICING...
Страница 66: ...56 VL5 WASH LUMINAIRE SERVICE MANUAL Notes...
Страница 74: ...64 VL5 WASH LUMINAIRE SERVICE MANUAL Notes...
Страница 118: ...108 VL5 WASH LUMINAIRE SERVICE MANUAL VL5 PCB Assembly Components Kit cont Figure 3 30 VL5 PCB Assembly Components Kit...
Страница 121: ...VL5 WASH LUMINAIRE SERVICE MANUAL 111 VL6 PCB Assembly Components Kit cont Figure 3 31 VL6 PCB Assembly Components Kit...
Страница 122: ...112 VL5 WASH LUMINAIRE SERVICE MANUAL Notes...
Страница 137: ...A TECHNICAL BULLETINS...
Страница 139: ...VL5 WASH LUMINAIRE SERVICE MANUAL 129 WIRING DIAGRAMS VL5 VL5B Wiring Diagram...
Страница 140: ...VL5 WASH LUMINAIRE SERVICE MANUAL 130 VL5Arc Wiring Diagram CONNECTOR LEGEND DETAIL A SEE DETAIL A...
Страница 141: ...VL5 Wash Luminaire Service Manual Version as of October 26 2011 PRG part number 02 9634 0010 F...
Страница 142: ...Production Resource Group Dallas Office 8617 Ambassador Row Suite 120 Dallas Texas 75247 www prg com...