TROUBLESHOOTING
Other Errors
Error Code
Explanation
Solution
Ballast Errors: Parity, Overrun,
Bad Header, Msg Too Long,
Ballast Comm Error
Various ballast errors
Check ballast comm cable/connections
Check Mains fuses, located on LVS
Ballast Heat Sink Over Temp
Ballast too hot
Check fans
Ballast Lamp EOL H/L Voltage
Limit
Lamp life limit exceeded
Check lamp
Ballast Line Voltage Low
Wrong voltage to strike
Check power connection
Ballast Short Detected
Short circuit on ballast output
Check wiring
Ballast Timeout: Lamp Strike
Lamp failed to strike
Check igniter, lamp
CAN Comm Error
Stopped receiving CAN messages
from motion processor
Check CAN cables/connections, motor
control board
Crossload Timeout
Crossload execution took too long
due to error
Remove any incoming DMX, retry
Data not crossload format
Data in memory is not proper format
for crossload
Load software via computer
DMX busy: cancel crossload
Cannot execute crossload
with traffic on DMX line
Remove incoming DMX control
for cross load
DMX: UART transmit error
Transmit buffer busy when trying to send
Remove any incoming DMX, retry
Fuse Blown
One or more fuses are blown
Check fuse on specified board
Gobo out of zero range
When zeroing gobo wheels, the wheel is
too far away from zero to set the position
Move wheel closer to home position
before zero command
Head Fan Error
Fan not running properly
Check fan
In Free Mode: Can’t Lock
Free mode is enabled
Use pan/tilt menu to change
from "free" to "lock"
Lamp Off
Fan Error: Cannot strike lamp
while any fan is in error state
Check fan, fan cabling
Lamp Off: Over Temperature
Head temperature too high
Check fans
Lamp over threshold
Lamp hours
above recommended maximum
Change lamp
Must Unlock via Free Option
Lock is enabled
Use pan/tilt menu to change
from "lock" to "norm"
Plenum Fan Error
Fan not running properly
Check fan
PMD Motion Error
Mechanism's actual position is too far
from its commanded position
Check mechanism motion
Framing Motor Disabled
Framing not running properly
Recalibrate, check mechanism motion
Stack Fan Error
One or more stack fans
not running properly
Check fan, fan cabling
Temp over threshold
Temperature too high
Check fans/filters
Tip Fan Error
Fan not running properly
Check fan
UPE Fans Error
Upper Enclosure fans
not running properly
Check fan, fan cabling
Yoke Fan Error
Fan not running properly
Check fan
Содержание BEST BOY HP SPOT LUMINAIRE
Страница 1: ...SOFTWARE VERSION 3 03 WWW PRG COM BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL...
Страница 10: ...PAGE VIII BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL TABLE OF CONTENTS...
Страница 13: ...1 DESCRIPTION This chapter contains an overview of Best Boy HP spot luminaire components COMPONENTS...
Страница 33: ...BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL TROUBLESHOOTING PAGE 23 Best Boy HP Menu Map...
Страница 34: ...PAGE 24 BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL TROUBLESHOOTING Best Boy HP Menu Quickstart...
Страница 35: ...BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL TROUBLESHOOTING PAGE 25 Best Boy HP Menu Quickstart Con t...
Страница 36: ...PAGE 26 BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL TROUBLESHOOTING Best Boy HP Menu Quickstart Con t...
Страница 37: ...BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL TROUBLESHOOTING PAGE 27 Best Boy HP Menu Quickstart Con t...
Страница 38: ...PAGE 28 BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL TROUBLESHOOTING Best Boy HP Menu Quickstart Con t...
Страница 39: ...BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL TROUBLESHOOTING PAGE 29 Best Boy HP Menu Quickstart Con t...
Страница 40: ...PAGE 30 BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL TROUBLESHOOTING Best Boy HP Menu Quickstart Con t...
Страница 118: ...PAGE 108 BEST BOY HP SPOT LUMINAIRE SERVICE MANUAL MAINTENANCE MAINTENANCE NOTES...
Страница 235: ...A TECHNICAL SPECIFICATIONS BEST BOY HP SPOT LUMINAIRE BEST BOY ROAD CASE...