PREVOST Le Mirage XL II Ultimate Скачать руководство пользователя страница 29

 

XL2 SLIDE-OUT SERVICE MANUAL 

 

6.  Take note of the new serial number with 

revision (RV:) and version (V:) identifications 
to inform Prevost service department for 
controller tracking. 

 

Caution: The new slide-out logic controller must 
be programmed as described in section 13.3.4 
and 13.3.5.  

 

 

 

FIGURE 

38

 

:

 SLIDE

-

OUT BREAKERS

 

13.3.3 EPROM memory chip replacement 

Caution: Do not leave the EPROM memory chip 
installed on the wrong side for a long time. The 
EPROM is installed on the wrong side when the 
logic controller power LED is slightly light.  

 
1.  Remove the logic controller from the 

electrical panel (13.3.2). 

 
2.  From behind the controller, unscrew the two 

cover screws. Keep the screw washer 
(figure 39). 

 
3.  Remove the back cover and the gasket. 
 
4.  With a small screwdriver, remove gently the 

chip from its socket. 

 
5.  Install a new chip so the groove is on the 

right side. Make sure each terminal is well 
seated in its socket. Beware not to bend the 
processor terminals. Press the chip in place. 

 
6.  Replace the gasket and the cover, and 

screw them back. 

 

7.  Write the new software version (written on 

the chip) on the controller sticker (if it had 
changed), and inform Prevost service 
department for controller tracking. 

 

 

FIGURE 

39

 

:

 EPROM MEMORY CHIP LOCALIZATION

 

 
8.  Reinstall the controller  on the electrical 

panel. 

13.3.4 Rear slide-out program set-up 

Caution:  Never press the slide-out control 
switch and the controller black push-button 
simultaneously. This will change the controller 
bit mode and make the controller non functional. 

 
1.  The slide-out must be retracted and all the 

pins locked. 

 
2.  Trip the 4

th

  breaker from the top (there are 

six breakers). It will cut off the rear logic 
controller electrical power (see figure 38). 

 
3.  Without starting the engine, turn the ignition 

key to the "ON" position. 

 
4.  With a small screwdriver, push and hold the 

logic controller black push-button and set 
the 4

th

 breaker (see figure 38 and figure 40). 

Hold the push-button depressed until the 
logic  controller "OUT6" green LED goes on 
(see figure 52). The green LED confirms that 
the rear slide-out program is set in the logic 
controller memory. 

 

Note: If by error, the rear slide-out logic 
controller program is loaded in the front slide-out 
logic controller memory, it becomes necessary 
to set-up the front slide-out logic controller. The 

R3 

29 

May 3, 2002 

Содержание Le Mirage XL II Ultimate

Страница 1: ...PREVOST SLIDE OUT TECHNOLOGY THE ULTIMATE CLASS CONVERSION BUS SHELLS SLIDE OUT SERVICE MANUAL RELEASE 3...

Страница 2: ...3 FRONT SLIDE OUT LOWER RACK REPLACEMENT 14 4 4 REAR SLIDE OUT LOWER RACK REPLACEMENT 14 5 PINION 15 5 1 MAINTENANCE 15 5 2 UPPER SHAFT PINION REPLACEMENT 15 5 3 FRONT SLIDE OUT DRIVER SIDE LOWER SHA...

Страница 3: ...ERS 27 13 3 1 Motor controller replacement 28 13 3 2 Logic controller replacement 28 13 3 3 EPROM memory chip replacement 29 13 3 4 Rear slide out program set up 29 13 3 5 Slide out stroke limits set...

Страница 4: ...FIGURE 15 PIN RECEPTACLE ON GLASS 13 FIGURE 16 PIN RECEPTACLE ON STAINLESS STEEL PANELS 13 FIGURE 17 FRONT SLIDE OUT ROOF REINFORCING ROD 13 FIGURE 18 BOTTOM RACK 14 FIGURE 19 PILLOW BLOCK SUPPORTING...

Страница 5: ...BOTTOM PANEL INSTALLATION 34 FIGURE 47 TOP AND BOTTOM PANEL INSTALLATION 34 FIGURE 48 WINDOWS ABOVE SIDE PANELS 34 FIGURE 49 WINDOW LOCATED OVER THE CORNER PANEL 35 FIGURE 50 PINION PILLOW BLOCK ADJUS...

Страница 6: ...XL2 SLIDE OUT SERVICE MANUAL FIGURE 1 SLIDE OUT MECHANICAL COMPONENTS R3 6 May 3 2002...

Страница 7: ...tight and that no damage or deformation has taken place for both the side and the upper stoppers 1 1 2 Adjustment 1 Adjust the side inner stoppers at 1 8 from the vehicle structure stoppers and tight...

Страница 8: ...ttom racks Rise up the tables to support the slide out without lifting it 4 From inside the vehicle loosen the upper shaft pillow block nuts and remove the shims behind the pillow blocks Keep note of...

Страница 9: ...lf and or its seal When moving the slide out check constantly its four corners from inside and outside to avoid contact with the locking pins and or the vehicle structure 2 Bring the slide out close t...

Страница 10: ...ocedure 1 3 1 6 REAR SLIDE OUT INSTALLATION The procedure for installing the rear slide out is almost the same as the procedure for the front slide out Before adjusting the stroke limits procedure 1 4...

Страница 11: ...ntrol panel while the ignition key is switched to the ON position When the tag axle is unloaded switch the ignition to the OFF position 4 Loosen the locking pin nuts 5 Align the locking pin with the s...

Страница 12: ...rew 4 Using a compressed air nozzle manually retract the locking pin 5 Slide the pin unlocked sensor PU in the air cylinder groove 6 Place the PU sensor in the zone where it is activated Move slowly t...

Страница 13: ...plastic cap back on 9 One by one replace the threaded rods with the washers and the screws FIGURE 16 PIN RECEPTACLE ON STAINLESS STEEL PANELS 10 Clean excess sealant with alcohol 11 Readjust the lock...

Страница 14: ...e pinion 4 From inside the slide out unscrew all the rack screws figure 2 and figure 3 5 Move the pinion away from the rack and remove the rack from its location by pulling it out 6 Remove the old wat...

Страница 15: ...after a load variation in the slide out section 5 6 Caution Make sure all keyless bushings are tightened to 125 lb ft before unlocking the pins or moving the slide out Refer to section 5 6 for torque...

Страница 16: ...lb ft before unlocking the pins or moving the slide out Refer to section 5 6 for torque wrench settings 5 3 FRONT SLIDE OUT DRIVER SIDE LOWER SHAFT PINION REPLACEMENT 1 Remove the front slide out as d...

Страница 17: ...motor side pinion only Remove the gearbox support see section 7 2 5 Remove the pinion and the keyless bushing from the shaft 6 Check the keyless bushing and the guide wheel condition and replace them...

Страница 18: ...shaft is not accessible when the slide out is installed Therefore it must be tightened before installing the slide out Follow these steps to adjust and synchronize the front slide out pinions 1 The sl...

Страница 19: ...e motor from the gearbox 4 Fasten the new motor to the gearbox using screws FIGURE 23 ELECTRIC MOTOR 5 Replace and tighten the motor holding metal strap figure 23 6 Re connect the motor electric cable...

Страница 20: ...6 2 13 Reinstall the universal joint and the jaw coupling on the right angle drive Use the motor output shaft to align the keyseats 14 For the front slide out Reinstall the reinforcement plate 8 RIGHT...

Страница 21: ...crews are tight 9 2 REPLACEMENT The jaw coupling replacement procedure is the same as for the right angle drive section 8 2 and 8 3 10 UHMW SLIDING PAD The UHMW sliding pads support the slide out and...

Страница 22: ...from moving Use Loctite 242 or equivalent product on all set screws 5 Paint the universal joints to prevent rust 11 3 VERTICAL SHAFT REPLACEMENT Use the same procedure as for the universal joint sect...

Страница 23: ...cted and pins unlocked A 3 port 2 position normally open valve is connected in line to the parking brake system and prevents the conductor from releasing the parking brake as long as both slide out ar...

Страница 24: ...e slide out sealing device is used to prevent any type of infiltration that may occur between the structure body and the slide out itself It is composed of an inflatable seal which is used as a primar...

Страница 25: ...ime Caution Always apply product in the same direction to prevent dirt from being brought back Caution Check before using any cleaning or adhesive product on seal panel or glass to prevent alteration...

Страница 26: ...nt on the exterior extrusion screws and between the extrusion the roof and the edges to prevent water infiltration figure 6 13 SLIDE OUT ELECTRICAL SYSTEM Warning Never modify the slide out electrical...

Страница 27: ...the driver side figure 35 LOGIC CONTROLLER The slide out logic controller is used to analyze the input signal conditions and activate outputs like the pneumatic valves and a predefined sequence progr...

Страница 28: ...up its memory section 13 3 4 FUSE INTERLOCK VALVE RELAY FIGURE 37 FUSE AND INTERLOCK VALVE RELAY Note The stroke limits and the rear slide out information are programmed in an EEPROM Then it is not n...

Страница 29: ...re version written on the chip on the controller sticker if it had changed and inform Prevost service department for controller tracking FIGURE 39 EPROM MEMORY CHIP LOCALIZATION 8 Reinstall the contro...

Страница 30: ...ze the slide out outer limit by pushing once the logic controller black push button see figure 40 The green LED OUT6 confirms that the stroke limit is set in the logic controller memory see figure 52...

Страница 31: ...of the logic 3 Loosen two metal screws on one side of the controller Unscrew the other side screws Remove the used safety controller and replace it by a new one 4 To reinstall the new safety controlle...

Страница 32: ...tween the side panels and the corner panels and also between side panels and bottom and top panels Apply sealant both inside and outside the slide out panels 14 3 CORNER PANELS REMOVAL Note The corner...

Страница 33: ...gure 15 and figure 16 Refer to figure 44 and figure 45 for adhesive tape and rivet position 14 5 TOP AND BOTTOM PANELS REMOVAL Note The top and bottom panels are made of aluminum sheets 1 Remove the s...

Страница 34: ...tween the windows and the structure Make sure not to damage the rubber seal between the windows 4 With a helper remove the window from the slide out For awning and sliding windows unscrew the window f...

Страница 35: ...e 6 Install the exterior extrusion as described in section 12 4 4 step 5 7 Install the finishing molding supports and the molding 16 WELDING PRECAUTION 1 Disconnect logic controller wiring connectors...

Страница 36: ...NT SLIDE OUT PIN VALVE 8 REAR SLIDE OUT PIN VALVE 9 FRONT SLIDE OUT RACK CLEANING 10 REAR SLIDE OUT RACK CLEANING 11 FRONT SLIDE OUT SEAL VACUUM VALVE 12 REAR SLIDE OUT SEAL VACUUM VALVE 13 PRESSURE R...

Страница 37: ...L2 SLIDE OUT SERVICE MANUAL FIGURE 52 SLIDE OUT LOGIC CONTROLLER LED PANEL PNEUMATIC CYLINDER SPRING PIN SLEEVE SEGMENT HEAD BASE SENSOR SWITCH INNER PIN FIGURE 53 LOCKING PIN ASSEMBLY R3 37 May 3 200...

Страница 38: ...limits section 13 3 5 B Check the linear position transducer potentiometer condition Regular flashing ten flashes every second 10 Hz and no abnormal LED flashing on the motor controller refer to secti...

Страница 39: ...air pressure inlet valve not completely opened C Locking pin not adjusted properly D Air line pin cylinder or pin valve obstruction malfunction or leakage E Locking pin sensor switch malfunction or w...

Страница 40: ...output LED 1 power LED 1 communication LED ERR and 1 diagnostic LED figure 52 When the ignition key is turned to the ON position the power LED comes on A slow flashing of the communication LED 0 1 se...

Страница 41: ...he motor controller section 13 3 1 C Check the safety controller and the electrical connections conditions Change the safety controller if necessary refer to section 13 3 7 Reset the power on the cont...

Страница 42: ...n section 5 6 B Readjust the stroke limits section 13 3 5 Slide out stops before having reached the limits without control switch LED light A Bad stroke limit adjustment A Readjust the stroke limits s...

Страница 43: ...ated the inflatable seal B Vacuum switch malfunction or bad set up C Excessive load on roof or bad roof reinforcing rod adjustment D Guide wheel excessive wear E Plastic stopper bad adjustment F Seal...

Страница 44: ...extended 2000 lb Maximum load when moving 1200 lb When the load is distributed in the slide out to prevent a deflection of the inside lower member over 1 4 that could damage the seal FIGURE 54 FRONT...

Страница 45: ...XL2 SLIDE OUT SERVICE MANUAL FIGURE 56 KEYLESS BUSHING INSTALLATION INSTRUCTION R3 45 May 3 2002...

Страница 46: ...d against peak voltage 6 outputs High Side of continuous 2A with protection against spike voltage peaks produced by inductive loads 2 high side output relay device 10A continuous Operating supply volt...

Страница 47: ...ynchronize the upper shaft pinion Make sure the slide out does not move when locking or unlocking the pins If necessary readjust the locking pins Make sure the pin receptacle plastic caps are present...

Страница 48: ...ALL WIRES ARE 18 AWG EXCEPT WHEN SPECIFIED EFFECTIVE FROM SERIAL NUMBER Y 7450 TO 1 7718 AND FROM 1 7724 TO 1 7773 2002 04 26 XL2 DOUBLE SLIDE OUT ELECTRIC DIAGRAM RETROFIT...

Страница 49: ...XL2 SINGLE SLIDE OUT ELECTRIC DIAGRAM RETROFIT EFFECTIVE FROM SERIAL NUMBER Y 7450 TO 1 7718 AND FROM 1 7724 TO 1 7773 ALL WIRES ARE 18 AWG EXCEPT WHEN SPECIFIED 2002 04 26...

Страница 50: ...XL2 DOUBLE SLIDE OUT ELECTRIC DIAGRAM RETROFIT ALL WIRES ARE 18 AWG EXCEPT WHEN SPECIFIED 2002 04 26 EFFECTIVE FROM SERIAL NUMBER Y 7003 TO Y 7446...

Страница 51: ......

Страница 52: ......

Страница 53: ......