Troubleshooting
The troubleshooting below is for the most common PreView
®
display.
Refer to the particular display manual for errors code descriptions.
Display Status LED is not illuminated.
Verify that DC power (9-33 V) is applied to the sensor.
Verify that the cable between the sensor and display is connected.
Display Status LED is RED.
Check connection between display and sensor.
Display Status LED is RED and one Yellow LED is illuminated.
LED Error Code
Possible Reason
LED #5 on
No communication with any sensor(s)
LED #4 on
Built in Self-Test Error – Contact Factory
LED #3 on
Missing sensor(s)
Display Status LED is RED and all yellow LEDs are illuminated.
A sensor blockage indication - verify that the sensor face is clean.
All the display LEDs are illuminated when sensor is mounted.
Verify the sensor is pointing outward from the vehicle in an open area
with no obstructions. This may require removing the mounting screws
and lifting the sensor out and away from the rear of the vehicle. If the
display LEDs are not active when moved away from the vehicle, but
are active when mounted, then the sensor’s mounting position will
have to be moved.
Sensor is detecting the ground, indicated by a few of the display LED’s
being lit.
In an open field, either move the sensor up higher or slightly angle the
sensor upward 2 to 5 degrees. The minimum recommended mounting
height is 24 inches.
Содержание Sentry ST82 Series
Страница 4: ......
Страница 18: ...Tel 386 3 4900 800 http radar electronics com 3702008A Copyright 2016 Page 14 Figure 14 Object Reflection...
Страница 23: ...Tel 386 3 4900 800 http radar electronics com 3702008A Copyright 2016 Page 19...
Страница 24: ...developed and manufactured in www radar electronics com e mail info radar electronics com tel 00386 3 4900 800...
Страница 25: ...Tel 386 3 4900 800 http radar electronics com 3702008A Copyright 2016 Page 21...