Product Description

A  feature  rich  mains  controller  allowing 

switch  users  to  control  up  to  two 

electrical  appliances  with  wired  or 

wireless switches.

ENERGISE

 includes SimplyWorks

®

 wireless  

technology,  allowing  interference  free 

activation of appliances at up to 10 metres.

Six  selectable  modes  enable  the  user 

to  choose  how,  and  for  how  long,  the 

appliance(s) will be turned on. 

Four modes give independent switch and 

appliance  activation:  two  further  modes 

provide  co-operative  control  of  both 

appliances.

ENERGISE

 will accept any wired switch or 

the  SimplyWorks

®

  SWITCH  125

SWITCH 

75

SEND

; or any combination of these.

New

Features

Added

Содержание Simplyworks ENERGISE

Страница 1: ...ology allowing interference free activationofappliancesatupto10metres Six selectable modes enable the user to choose how and for how long the appliance s will be turned on Four modes give independent switch and appliance activation two further modes provide co operative control of both appliances ENERGISE will accept any wired switch or the SimplyWorks SWITCH 125 SWITCH 75 SEND or any combination ...

Страница 2: ...he event of an emergency The unit is not an electrical isolation means You should treat the appliances connected to the unit as capable of being energised at any time even unexpectedly Ensure that appliances are unplugged from the unit before attempting any operation which may constitute a hazard even if the appliance is not energised Do not disassemble and do not attempt to replace a worn or dama...

Страница 3: ...d of time from 1 to 15 minutes Subsequent presses of any switch do not extend the timer period TIMED SECONDS allows the appliance to operate for a preset period of time from 4 seconds to 40 seconds Subsequent presses of any switch do not extend the timer period CO OP requires at least one switch to be paired connected to both channels Both appliances operate when at least one switch on each channe...

Страница 4: ...1 2 3 4 5 6 7 8 9 10 ...

Страница 5: ...ED 7 8 flashes rapidly The pairing information for all three switches will be erased allowing you to start over Output Status The Pair LEDs also indicate the status of the output channels 1 2 If channel 1 is activated Pair LED 1 7 lights and if channel 2 is activated Pair LED 2 8 lights The LEDs still blink briefly if a wireless transmission is received Control Modes ENERGISE has six modes of cont...

Страница 6: ...ither of these modes the other channel is set back to its previous setting Settings are saved when the LEDs are extinguished and are retained even whilst the power is off Turning Outputs Off If a channel is set to a timed mode the period for which the appliance is energised may be ended prematurely by pressing either the Mode 3 or Period 4 buttons briefly Safe Operation Your safety and that of the...

Страница 7: ...be returned to Pretorian Technologies Ltd or an authorised distributor Technical Specification Input Output Power UK and Europe 230Vac 8A 50Hz USA 120Vac 8A 60Hz refers to the total of all connected appliances Fuse ratings UK Fused at 10A in plug Panel fuse on rear of unit 8A 20mm x 5mm diameter Europe No fuse in plug Panel fuse on rear of unit 8A 20mm x 5mm diameter USA No fuse in plug Panel fuse...

Страница 8: ...eparatewallsockettotest Replaceifnecessary Ensurethatswitchissettoon Releasetheswitch Wireless switch does not operate appliance Switchnotpaired watch forPairLEDblinking Unitissetto Co operativemode Appliancenotfunctioning Appliancehasitsown powerswitch Anotherswitchonthe samechannelisalready pressed Followpairingsequenceforrequired channel Changetoanothermode Plugintoaseparatewallsockettotest Rep...