background image

Pairing with Wireless Switches

Place 

SWITCH  125

  or 

SWITCH  75

  close  to 

ENERGISE

  and  briefly  press  Pair  1  button  [5]  on 

ENERGISE

. Pair LED 1 [7] will flash slowly. Immediately press the Pair button on the wireless 

switch. Pair 1 LED will continue to flash slowly until pairing is complete when the LED will light 
steadily for 5 seconds.
You can pair up to three wireless switches with each channel of 

ENERGISE

, allowing collaboration 

between several users. If you attempt to pair a fourth switch, the switch that was used least 
recently will be replaced with the new one. The other two switches are unaffected.
Repeat the procedure to pair further wireless switches with pair 2 button [6] on 

ENERGISE

. Pair 

LED 2 [8] will flash during the process.
The procedure to pair 

SEND

 with 

ENERGISE

 is exactly as for 

SWITCH 125/SWITCH 75

; or any 

combination of these. 
Whenever 

ENERGISE

  receives  a  wireless  transmission,  the  Pair  LED  [7]/[8]  blinks  as  an 

acknowledgement. This is useful when finding which switch is paired with a particular channel.
 If at any stage you would like to clear the pairing on either channel, press and hold its respective 
pairing button [5/6] until the pairing LED [7/8] flashes rapidly. The pairing information for all 
three switches will be erased, allowing you to start over.

Output Status

The Pair LEDs also indicate the status of the output channels [1]/[2]. If channel 1 is activated, 
Pair LED 1 [7] lights and if channel 2 is activated, Pair LED 2 [8] lights. The LEDs still blink briefly 
if a wireless transmission is received.

Control Modes

ENERGISE

  has  six  modes  of  control,  four 

of  which  can  be  used  with  either  one  or  two 
switches,  and  two  modes  which  require  two 
switch operation.
One or two switch modes:

• 

DIRECT

: the appliance activates while any 

switch  is  held  down  and  stops  when  all 
switches are released.

• 

LATCH

: one press activates the appliance 

the next press stops the appliance.

• 

TIMED  SECONDS

:  one  press  turns  the 

appliance  on  for  the  number  of  seconds 
selected.

• 

TIMED  MINUTES

:  one  press  turns  the 

appliance  on  for  the  number  of  minutes 
selected.

NOTE

:  In  the  above  modes,  when  using  two 

switches  and  two  appliances,  the  operating 
modes  may  be  different  for  each  of  the  two 
channels  e.g.  one  appliance  operating  in 
DIRECT  mode  and  one  appliance  operating  in 
TIMED SECONDS.
Two switch modes:

• 

CO-OPERATIVE:  At  least  one  switch  on 
each channel must be held down for both 
appliances to operate.

• 

ON/OFF: Pressing any switch on channel 
1  turns  both  appliances  on;  pressing 
any  switch  on  channel  2  turns  both 
appliances off.

Содержание Simplyworks ENERGISE

Страница 1: ...ology allowing interference free activationofappliancesatupto10metres Six selectable modes enable the user to choose how and for how long the appliance s will be turned on Four modes give independent switch and appliance activation two further modes provide co operative control of both appliances ENERGISE will accept any wired switch or the SimplyWorks SWITCH 125 SWITCH 75 SEND or any combination ...

Страница 2: ...he event of an emergency The unit is not an electrical isolation means You should treat the appliances connected to the unit as capable of being energised at any time even unexpectedly Ensure that appliances are unplugged from the unit before attempting any operation which may constitute a hazard even if the appliance is not energised Do not disassemble and do not attempt to replace a worn or dama...

Страница 3: ...d of time from 1 to 15 minutes Subsequent presses of any switch do not extend the timer period TIMED SECONDS allows the appliance to operate for a preset period of time from 4 seconds to 40 seconds Subsequent presses of any switch do not extend the timer period CO OP requires at least one switch to be paired connected to both channels Both appliances operate when at least one switch on each channe...

Страница 4: ...1 2 3 4 5 6 7 8 9 10 ...

Страница 5: ...ED 7 8 flashes rapidly The pairing information for all three switches will be erased allowing you to start over Output Status The Pair LEDs also indicate the status of the output channels 1 2 If channel 1 is activated Pair LED 1 7 lights and if channel 2 is activated Pair LED 2 8 lights The LEDs still blink briefly if a wireless transmission is received Control Modes ENERGISE has six modes of cont...

Страница 6: ...ither of these modes the other channel is set back to its previous setting Settings are saved when the LEDs are extinguished and are retained even whilst the power is off Turning Outputs Off If a channel is set to a timed mode the period for which the appliance is energised may be ended prematurely by pressing either the Mode 3 or Period 4 buttons briefly Safe Operation Your safety and that of the...

Страница 7: ...be returned to Pretorian Technologies Ltd or an authorised distributor Technical Specification Input Output Power UK and Europe 230Vac 8A 50Hz USA 120Vac 8A 60Hz refers to the total of all connected appliances Fuse ratings UK Fused at 10A in plug Panel fuse on rear of unit 8A 20mm x 5mm diameter Europe No fuse in plug Panel fuse on rear of unit 8A 20mm x 5mm diameter USA No fuse in plug Panel fuse...

Страница 8: ...eparatewallsockettotest Replaceifnecessary Ensurethatswitchissettoon Releasetheswitch Wireless switch does not operate appliance Switchnotpaired watch forPairLEDblinking Unitissetto Co operativemode Appliancenotfunctioning Appliancehasitsown powerswitch Anotherswitchonthe samechannelisalready pressed Followpairingsequenceforrequired channel Changetoanothermode Plugintoaseparatewallsockettotest Rep...

Отзывы: