Data badge -
Lower part of front frame
Type of gas -
This cooker must only be
used with either Natural Gas only or LP
Gas only, as specified on the appliance
data badge.
Gas category -
Natural Gas -
I
2H
, LP
Gas -
I
3+
Pressure setting
G20 Natural Gas @ 20 mbar
G30 Butane @ 28-30 mbar
G31 Propane @ 37 mbar
Pressure test point -
Use the oven
injector
Aeration -
Fixed
Appliance class -
Class 1, freestanding
Grill -
Grill burner is surface combustion
type. Spark gaps 3 - 4mm.
Hob -
Burners have burner heads and
caps which are removable for cleaning.
Concealed electrodes to each burner.
Ovens -
Oven burners are sheet steel,
with pierced ports in stainless steel flame
strip.
Spark Gap:
3 - 4mm.
Flame super -
vision
: Expansion type.
Thermostat phial
:
Front centre of oven roof.
Electrical supply
220 - 240V ~ 50Hz
Spark generator:
Mains operated 7 outlet
controlled by a single push button switch at the
left hand side of the facia to individual
electrodes.
Warning:
This cooker must be earthed.
Countries of destination -
GB - Great
Britain,
Please make a note of the model and seri-
al numbers for this appliance in the spaces
provided;
31
Technical Data
Model No
Serial No
08 27360 00 -Prestige GDO 19/9/07 13:19 Page 29
Содержание G50DO