EN • 40
ENGLISH
FRANCAIS
NEDERLANDS
ES
p
A
ño
L
IT
ALIAN
o
DE
u
TSCH
664Y3300
error mode [avec code]
ERROR
indicates the last error,
as well as the status of the boiler and the current values
of this error.
Key
Display
MODE
communIcatIon mode [with code]
This mode displays communication between the boiler
and the control module, the optional interface kit or
the optional programmable room thermostat
Key
Display
MODE
Key
Display
Description of the
parameters
STEP
Code of last error
STEP
Status of the boiler
at the time of the error
STEP
Flow temperature T1
at the time of the error
STEP
Return temperature T2
at the time of the error
STEP
Hot water temperature T3
at the time of the error
STEP
Outdoor temperature T4
at the time of the error
Key
Display
Description of the
parameters
STEP
No communication
Communication only between the
boiler module and the optional
control module.
Communication between all the
connected appliances.
Key
Display
Description of the
parameters
MODE
Fan speed
STEP
The fan’s current speed
is 5,500 rpm.
fan mode [with code]
mCBA pARAmETERS FoR THE SpECIALIST
Содержание 120