34
The TLM can use an input of either 115 VAC or 220
VAC (factory set at 115 VAC).
Input power is connected by means of the front panel
“A.C. IN” connector and fused with either a 100mA fuse
for 115 VAC, or a 50mA fuse for 220 VAC.
These jumpers can be accessed by removing the six
screws securing the cover and then pulling the cover off
from the front.
115 VAC = Jumpers A & C
220 VAC= Jumper B Only
TLM Cam Switch Wiring Connections
Tonnage Load Monitor
(optional)
Mounting & Connecting
Figure 4
TLM Printed Circuit Board
Figure 4a
Front Panel A.C. Power Connections