36
channel 2 is activated.
OFF /
No priority channel is activated.
The default priority channels are channel
9/AM
(
EMG1
) and channel
19/
AM
(
EMG2
).
See the
EMG SET 1
and
EMG SET 2
menus page 38 to
set
priority channels.
Note:
Activating a priority channel prevents changing the modulation
mode (AM / FM / UK), scanning the channels or activating the
PA
mode.
If the
KEY BEEP
function is activated, an error beep sounds.
“EMG”
and the
channel blink to indicate unauthorized handling. Turn the switch (
11
) to the
OFF position to use these functions.
12) CB/PA
Switch between
CB
and
PA
(Public Address) mode.
An external optional speaker can be connected to the unit to the PA.SP.
jack on the rear panel. (
D
). Turn the
MIC GAIN
knob (
4
) to adjust the
PA
volume.
For details on operating in PA mode, see the
PA SETTING
menu on page
39.
13) MODE (AM/FM/FM UK)
Press
MODE
key (
13
) to
select
the modulation mode: AM or FM. Selected
mode is displayed on LCD.
Your modulation mode has to correspond to the one of your correspondent.
-
Frequency Modulation / FM:
for nearby communications on a flat open
field.
-
Amplitude Modulation / AM:
communication on a field with relief and
obstacles at middle distance (the most used).
In U configuration only:
The
MODE
key (
13
) allows to
select
the
ENG
or
CEPT
frequency band.
“UK”
is displayed when the
ENG
frequency band
is selected. When the
CEPT
frequency band is selected,
“UK”
disappears
from the display (see table on page 57).
14) BARGRAPH
Indicates
the reception level and the emitted power level.
15) 6 PIN MICROPHONE PLUG
The plug is located on the front panel of the transceiver and makes the
setting of the equipment into the dashboard easier.
See Cabling Diagram page 60.
16) USB CHARGING SOCKET
The
USB
socket (
16
) can be used to charge smartphones, tablets or other
rechargeable devices with 5 V - 2.1 A.
17) PTT
Transmission key, press to
transmit
a message,
is displayed and release
to
listen to
an incoming communication,
disappears.
TOT (Time Out Timer)
If the
PTT
switch (
17
) key is pressed for more than 5 minutes, the display starts
blinking and the transmission
ends
. A beep will sound until the
PTT
switch
(
17
) key is released.
18) UP/DN BUTTONS ON MICROPHONE ~ SCAN
UP/DN BUTTONS ON MICROPHONE
(short press)
In normal use, press
UP
/
DN
buttons (
18
) on the microphone to
change
the
channel.
UP
to
increase
and
DN
to
decrease
the channel.
In
MENU
mode [press the
PUSH
knob (
6
) for about 3 seconds to activate this
mode
(see §
MENU
page 37)
], the
UP
or
DN
buttons (
18
) allows to
select
the menu to be set.
See
ROTARY “PUSH” KNOB
page 34
.
SCAN
(long press)
Press and hold the
UP
or
DN
button (
18
) for ± 7 seconds or until a beep
sounds to activate the
SCAN
function. The dot between the two channel
digits flashes to indicate that the function is active.
The scanning stops as soon as there is a busy channel. The scanning auto-
matically starts 3 seconds after the end of the transmission and no key is
activated during 3 s. In
SCANNING
mode, turn the
PUSH
rotary knob (
6
) or
press the
UP
/
DN
buttons (
18
) on the microphone to change scan direction.
Press
PTT
switch (
17
) to exit
SCAN
. The dot between the two channel digits
disappears from LCD.