Premier Mounts PSD-TL Скачать руководство пользователя страница 19

CTM-MS2 

Installation Instructions 

Visit the Premier Mounts website at http://www.premiermounts.com

 

Page 9

Installing the Mounting Brackets (cont’d)
Griplate

 Installation

Flat Panel

Universal Washer

Universal Spacer

Mounting Bracket

Mount Point

Mounting Screw

Premier Mounts’ Universal Washers are designed to 

accommodate the various M4, M5, M6 and M8 hole 

sizes required by flat panels.

 Do not place excessive pressure on the back of 

the flat panel, as this may damage the flat panel. 

The Universal Washer must be installed between 

the head of the mounting screw and the mounting 

bracket as shown.

 

 Does the flat panel have: 

 

Recessed mount points?

 

Uneven mount points?

 

A curved back?

 

Any obstruction near the mount point?

If 

Yes

, you must install Universal Spacers.  Remove the 

mounting brackets, Universal Washers, and mounting 

screws from the back of the flat panel.  

Proceed to the 

“Universal Spacer Installation” below

 

If 

No

skip to the “Attaching the Mounting Bracket to 

the Flat Panel” on page 10

Universal Spacer Installation

Premier Mounts’ Universal Spacers allow you to 

attach  the mounting bracket to flat panels which have 

recessed or uneven mount points. Each Universal 

Spacer adds ¼˝ to the distance between the mounting 

bracket and the flat panel.

The Universal Spacers must be stacked and 

oriented as shown.

The Universal Spacers must only be installed 

between the mounting bracket and the flat panel.

The Universal Spacers will fit M4, M5, M6 and M8 

screw sizes.
Proceed to the 

“Attaching the Mounting Bracket to 

the Flat Panel”

 section.

M8 

M5, M6 

M4

¼˝

Содержание PSD-TL

Страница 1: ...e Anaheim CA 92806 USA USA and Canada Phone 800 368 9700 Fax 800 832 4888 EUROPE Swallow House Shilton Industrial Estate Shilton Coventry England CV79JY Phone 44 0 2476 614700 Fax 44 0 2476 614710 Oth...

Страница 2: ...LD RESULT IN SERIOUS PERSONAL INJURY OR EVEN DEATH THE OPTIONAL SHELF IS ONLY CAPABLE OF HOLDING 25LBS OR LESS SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE INSTALLATION OF THIS PRODUCT US...

Страница 3: ...e are parts missing and or damaged please stop the installation and contact Premier Mounts 800 368 9700 PSD TL Base Qty 1 Support Poles Qty 2 Screwdriver Not Supplied 1 2 Socket and Socket Wrench Not...

Страница 4: ...ontal or vertical position with PSM and RTM L S mounts only The flat panel height is adjustable to any point along the stand s vertical support poles to achieve the perfect viewing level The PSD TL ma...

Страница 5: ...the back of the mounting columns Step 3 Tighten set screw with the supplied Allen wrench Do not over tighten the screws Step 1 Install the PSD SPA mount adapter over the top of the support poles and s...

Страница 6: ...afety knobs supplied with the CTM mount Step 4 Insert and tighten two 2 M6 x 30mm lateral shift screws supplied with the CTM mount on the bottom of the mounting arms These screws will prevent the flat...

Страница 7: ...with the four 4 M10 x 12 bolts and flat washers supplied Installing the PSM Support Poles PSD SPA Adapter Directional Arrow PSM Back Plate M10 x 12mm Bolts M10 Flat Washers Step 2 Raise the flat panel...

Страница 8: ...height and secure the shelf using four 4 M8 x 10mm set screws Step 4 Tighten these screws using the supplied Allen wrench Do not install the optional shelf higher than 39 If using a shelf please inst...

Страница 9: ...Installation Instructions Page 9 PSD TL Technical Specifications All measurements are in inches mm...

Страница 10: ...CLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE PREMIER MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO INABILITY TO USE ITS P...

Страница 11: ...nd Canada Phone 1 800 368 9700 Fax 1 800 832 4888 Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 CREATING POSITIVE CUSTOMER EXPERIENCES 9531 000 311 08 EUROPE Unit 3 The Moorings Business...

Страница 12: ...rform the assembly procedure Personal injury and or property damage can result from dropping or mishandling the flat panel If mounting to wall studs or ceiling studs make sure that the mounting screws...

Страница 13: ...before beginning installation If there are parts missing and or damaged please stop the installation and contact Premier Mounts at 1 800 368 9700 CTM MS2 Tilting Wall Mount Assembly Components Wall P...

Страница 14: ...ware M4 x 16mm Screw Qty 6 M4 x 25mm Screw Qty 6 M5 x 16mm Screw Qty 6 M5 x 25mm Screw Qty 6 M5 x 30mm Screw Qty 6 M6 x 30mm Screw Qty 6 M8 x 16mm Screw Qty 6 M8 x 25mm Screw Qty 6 M8 x 30mm Screw Qty...

Страница 15: ...g Arrow Lets you know which edge is the top Cable Electrical Cut Out Allows for easy cable access and power distribution installations Mounting Slots Allow for a variety of stud configurations and lat...

Страница 16: ...stud found Use a stud finder to determine the exact center of wall studs in the vicinity of the wall plate Use a pencil to mark the exact center of each of the wall studs Step 1 Step 2 Step 3 Two peop...

Страница 17: ...ng five 5 mounting locations along the center of each wall stud Two people are recommended for this step one person to level the wall plate and another person to drill the pilot holes Drill a pilot ho...

Страница 18: ...readed inserts to compare and verify their depth using the straw or toothpick s 1 8 allowance mark Locate the correct diameter screw for the threaded insert If the screw you selected is longer than th...

Страница 19: ...back Any obstruction near the mount point If Yes you must install Universal Spacers Remove the mounting brackets Universal Washers and mounting screws from the back of the flat panel Proceed to the Un...

Страница 20: ...your flat panel Secure each mounting bracket to your flat panel by inserting a minimum of two 2 screws per bracket Do not overtighten the mounting hardware Attaching the Mounting Brackets to the Flat...

Страница 21: ...he safety knurl knobs and instead chose to use the Panelock skip this section and proceed to the Panelock Installation section below The Panelock is a theft deterent device It comes with security hard...

Страница 22: ...Panel Friction Tilt Angle Place one hand at the center top edge of the flat panel Place the other hand on the center bottom edge of the flat panel Using the upper hand gently pull the top of the flat...

Страница 23: ...CTM MS2 Installation Instructions Visit the Premier Mounts website at http www premiermounts com Page 13 Technical Specifications All measurements are in inches millimeters...

Страница 24: ...R LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you thi...

Отзывы: