Premier Mounts PSD-TL Скачать руководство пользователя страница 12

CTM-MS2

Page 2 

Visit the Premier Mounts website at http://www.premiermounts.com

 

Installation Instructions

Contact Premier Mounts with any questions: 
(800) 368-9700
[email protected]

Contents

Warning Statements

Weight Limit

Maximum Flat Panel Weight: 

160 lbs.

THE WALL STRUCTURE MUST BE CAPABLE OF 
SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF 
THE FLAT PANEL. IF NOT, THE WALL STRUCTURE MUST 
BE REINFORCED. 

 PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND 

COMPLETELY UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION 

FOR FUTURE REFERENCE.

 PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED 

IN THESE INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS 

PERSONAL INJURY, OR EVEN DEATH.

 SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE 

PROPER SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.

 PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS 

PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY 

UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, 

DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR 

IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.

 

 At least two qualified people should perform the assembly procedure. Personal injury and/or property damage can result 

from dropping or mishandling the flat panel.

 

 If mounting to wall studs or ceiling studs, make sure that the mounting screws are anchored into the center of the wall studs 

or ceiling studs. Use of an edge-to-edge stud finder is recommended.

 

 It is recommended that a maximum of ⅝˝ plaster board be used when mounting to wooden studs.

 

 Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there  

are no electrical wires in wall. Cutting or drilling into an electrical line may cause serious personal injury.

 

 Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a 

water or gas line may cause severe property damage or personal injury.

 

 This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious 

personal injury.

 

 Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of 

impact.

Weight Limit. ............................................................................................................................................................. 2

Warning Statements. ................................................................................................................................................ 2

Installation Tools. ...................................................................................................................................................... 3

Parts List................................................................................................................................................................... 3

Mounting Hardware. ................................................................................................................................................. 4

Nylon Spacers and Flat Washers. ............................................................................................................................ 4

Features. .................................................................................................................................................................. 5

Installing the Wall Plate. ........................................................................................................................................... 6

Introduction. ................................................................................................................................................. 6

Installing the Mounting Brackets............................................................................................................................... 8

Selecting the Mounting Hardware. .............................................................................................................. 8

Griplate™ Washer Installation. .................................................................................................................... 9

Nylon Spacer Installation. ............................................................................................................................ 9

Attaching the Mounting Brackets to the Flat Panel. ................................................................................... 10

Mounting the Flat Panel.......................................................................................................................................... 10

Attaching the Flat Panel to the Wall Plate. ................................................................................................ 10

Safety Knurl Knob Installation. .................................................................................................................. 11

Locking Safety Screw Installation. ............................................................................................................. 11

Tilt Adjustment.

 .......................................................................................................................................... 11

Technical Specifications.

 ........................................................................................................................................ 12

Warranty. ................................................................................................................................................................ 13

Содержание PSD-TL

Страница 1: ...e Anaheim CA 92806 USA USA and Canada Phone 800 368 9700 Fax 800 832 4888 EUROPE Swallow House Shilton Industrial Estate Shilton Coventry England CV79JY Phone 44 0 2476 614700 Fax 44 0 2476 614710 Oth...

Страница 2: ...LD RESULT IN SERIOUS PERSONAL INJURY OR EVEN DEATH THE OPTIONAL SHELF IS ONLY CAPABLE OF HOLDING 25LBS OR LESS SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE INSTALLATION OF THIS PRODUCT US...

Страница 3: ...e are parts missing and or damaged please stop the installation and contact Premier Mounts 800 368 9700 PSD TL Base Qty 1 Support Poles Qty 2 Screwdriver Not Supplied 1 2 Socket and Socket Wrench Not...

Страница 4: ...ontal or vertical position with PSM and RTM L S mounts only The flat panel height is adjustable to any point along the stand s vertical support poles to achieve the perfect viewing level The PSD TL ma...

Страница 5: ...the back of the mounting columns Step 3 Tighten set screw with the supplied Allen wrench Do not over tighten the screws Step 1 Install the PSD SPA mount adapter over the top of the support poles and s...

Страница 6: ...afety knobs supplied with the CTM mount Step 4 Insert and tighten two 2 M6 x 30mm lateral shift screws supplied with the CTM mount on the bottom of the mounting arms These screws will prevent the flat...

Страница 7: ...with the four 4 M10 x 12 bolts and flat washers supplied Installing the PSM Support Poles PSD SPA Adapter Directional Arrow PSM Back Plate M10 x 12mm Bolts M10 Flat Washers Step 2 Raise the flat panel...

Страница 8: ...height and secure the shelf using four 4 M8 x 10mm set screws Step 4 Tighten these screws using the supplied Allen wrench Do not install the optional shelf higher than 39 If using a shelf please inst...

Страница 9: ...Installation Instructions Page 9 PSD TL Technical Specifications All measurements are in inches mm...

Страница 10: ...CLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE PREMIER MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO INABILITY TO USE ITS P...

Страница 11: ...nd Canada Phone 1 800 368 9700 Fax 1 800 832 4888 Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 CREATING POSITIVE CUSTOMER EXPERIENCES 9531 000 311 08 EUROPE Unit 3 The Moorings Business...

Страница 12: ...rform the assembly procedure Personal injury and or property damage can result from dropping or mishandling the flat panel If mounting to wall studs or ceiling studs make sure that the mounting screws...

Страница 13: ...before beginning installation If there are parts missing and or damaged please stop the installation and contact Premier Mounts at 1 800 368 9700 CTM MS2 Tilting Wall Mount Assembly Components Wall P...

Страница 14: ...ware M4 x 16mm Screw Qty 6 M4 x 25mm Screw Qty 6 M5 x 16mm Screw Qty 6 M5 x 25mm Screw Qty 6 M5 x 30mm Screw Qty 6 M6 x 30mm Screw Qty 6 M8 x 16mm Screw Qty 6 M8 x 25mm Screw Qty 6 M8 x 30mm Screw Qty...

Страница 15: ...g Arrow Lets you know which edge is the top Cable Electrical Cut Out Allows for easy cable access and power distribution installations Mounting Slots Allow for a variety of stud configurations and lat...

Страница 16: ...stud found Use a stud finder to determine the exact center of wall studs in the vicinity of the wall plate Use a pencil to mark the exact center of each of the wall studs Step 1 Step 2 Step 3 Two peop...

Страница 17: ...ng five 5 mounting locations along the center of each wall stud Two people are recommended for this step one person to level the wall plate and another person to drill the pilot holes Drill a pilot ho...

Страница 18: ...readed inserts to compare and verify their depth using the straw or toothpick s 1 8 allowance mark Locate the correct diameter screw for the threaded insert If the screw you selected is longer than th...

Страница 19: ...back Any obstruction near the mount point If Yes you must install Universal Spacers Remove the mounting brackets Universal Washers and mounting screws from the back of the flat panel Proceed to the Un...

Страница 20: ...your flat panel Secure each mounting bracket to your flat panel by inserting a minimum of two 2 screws per bracket Do not overtighten the mounting hardware Attaching the Mounting Brackets to the Flat...

Страница 21: ...he safety knurl knobs and instead chose to use the Panelock skip this section and proceed to the Panelock Installation section below The Panelock is a theft deterent device It comes with security hard...

Страница 22: ...Panel Friction Tilt Angle Place one hand at the center top edge of the flat panel Place the other hand on the center bottom edge of the flat panel Using the upper hand gently pull the top of the flat...

Страница 23: ...CTM MS2 Installation Instructions Visit the Premier Mounts website at http www premiermounts com Page 13 Technical Specifications All measurements are in inches millimeters...

Страница 24: ...R LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you thi...

Отзывы: