AFV
+
Series High Power Programmable AC Power Supply
6-119
6.10.8
Read Measurement Data
6.10.8.1
Output Side
Setup measurement mode
:
MEAS:MODE OUT\r\n
Read system error status
:
SYST:ERRor? \r\n
Read measurement data
:
MEAS:ALL? \r\n
Read running mode parameters
:
MEAS:PCYC? \r\n (For Step/Gradual Mode
operation)
6.10.9
Limit Current Settings
Setup the upper limit current
:
LIM:CURR 100.0\r\n
Note1
:
Once the output current exceeds the set value of upper limit current, the
device stops the output and report the fault.
Note2
:
The set value of upper current limit cannot be greater than the rated current
value.
6.11
System Error Code Description
6.11.1
System Error Code
The followings are the system error information in uint 32bit corresponding to
system error status.
Bit
Fault Description
0
R-phase IGBT1 Over current fault
1
R-phase IGBT2 Over current fault
2
R-phase IGBT3 Over current fault
3
R-phase IGBT4 Over current fault
4
S-phase IGBT1 Over current fault
5
S-phase IGBT2 Over current fault
6
S-phase IGBT3 Over current fault
7
S-phase IGBT4 Over current fault
8
T-phase IGBT1 Over current fault
9
T-phase IGBT2 Over current fault
Содержание AFV+ Series
Страница 12: ...1 6 8 1 Notice for Maintenance 8 125...
Страница 24: ...AFV Series High Power Programmable AC Power Supply 1 12 Figure 1 7 AFV Series Number Chassis Exterior...
Страница 34: ...AFV Series High Power Programmable AC Power Supply 2 22...
Страница 44: ...AFV Series High Power Programmable AC Power Supply 2 32 Figure 2 13 Remote Sensing Connection in use...
Страница 63: ...AFV Series High Power Programmable AC Power Supply 3 51 Press to move to the previous page of the next page...