Communication Example
6.10.1
Remote Control
Enter remote control mode
:
SYST:REM\r\n
Read rated capacity
:
LIM:POW?\r\n
Note
:
Read the rated capacity is used for checking if the communication works
normal and receive data successfully. (There is no answer for SYST:REMCommand)
6.10.2
Read Device Information
Read product information
:
SYST:INFO?\r\n
Read rated capacity
:
LIM:POW?\r\n
Read max. voltage
:
LIM:VOLT:HIGH?\r\n
Read min. voltage
:
LIM:VOLT:LOW? \r\n
Read max. frequency
:
LIM:FREQ:HIGH? \r\n
Read min. frequency
:
LIM:FREQ:LOW? \r\n
Read available function list
:
SYST:FUNC? \r\n
Read high/low level status
:
SOUR:VOLT:RANG:LOW? \r\n
Read running status
:
OUTP? \r\n
Note
:
User can select the needed information and send the corresponding
command in above.
6.10.3
Phase Angle Control
Setup phase angle value
:
INST:PHASe 0
,
240
,
120\r\n
Note 1: The output voltage waveform of all output mode, including the general, the
step and the gradual, are affected by the phase angle control.
Note2
:
The default phase angle value is
(
0
,
240
,
120
)
.
Содержание AFV+ Series
Страница 12: ...1 6 8 1 Notice for Maintenance 8 125...
Страница 24: ...AFV Series High Power Programmable AC Power Supply 1 12 Figure 1 7 AFV Series Number Chassis Exterior...
Страница 34: ...AFV Series High Power Programmable AC Power Supply 2 22...
Страница 44: ...AFV Series High Power Programmable AC Power Supply 2 32 Figure 2 13 Remote Sensing Connection in use...
Страница 63: ...AFV Series High Power Programmable AC Power Supply 3 51 Press to move to the previous page of the next page...