AFV
+
Series High Power Programmable AC Power Supply
6-108
6.3.8
SOUR:STEP:LOAD
Function Description
:
Setup all STEP data to controller MCU.
Command Description
:
SOUR:STEP:LOAD\r\n
Answer Command
:
None
Note
:
The command is optional.
6.3.9
SOUR:GRAD:VOLT
Function Description
:
Setup output voltage in Gradual Mode
Command Description
:
SOUR:GRAD:VOLT 1,110.0,220.0r\n
Parameter1
:
Group
(
1-12
)
Parameter2
:
Gradual start voltage of the group
Parameter3
:
Gradual end voltage of the group
Answer Command
:
None
6.3.10
SOUR:GRAD:FREQ
Function Description
:
Setup output frequency in Gradual Mode
Command Description
:
SOUR:GRAD:FREQ 1,50.0,60.0r\n
Parameter1
:
Group
(
1-12
)
Parameter2
:
Gradual start frequency of the group
Parameter3
:
Gradual end frequency of the group
Answer Command
:
None
6.3.11
SOUR:GRAD:TIME
Function Description
:
Setup time interval in Gradual Mode
Command Description
:
Mode 1
:
1 Hour, 1 Minute, 10.0 Second
:
SOUR: GRAD:TIME 1,1:1:100\r\n
Mode 2
:
1 Hour, 1 Minute, 10.00 Second
:
SOUR: GRAD:TIME 1,1:1:1000\r\n
Answer Command
:
None