background image

Page 6

For generator technical questions, please call 1-800-444-3353. 

For engine technical questions, please call 1-800-520-0882.

ITEM 61169 

        

SAFETY

Op
ERA
TION

M

AINTENANCE

SETU
p

Service precautions

1. 

Before service, maintenance, or cleaning:

a. 

Unplug all devices from the generator.

b. 

Turn the engine switch to its “OFF” position.

c. 

Allow the engine to completely cool.

d. 

Then, remove the spark plug cap 

from the spark plug.

2.  Keep all safety guards in place and in 

proper working order.  Safety guards include 

muffler, air cleaner, mechanical guards, 

and heat shields, among other guards.

3. 

Keep all electrical equipment clean and dry. 

  

Replace any wiring where the insulation is 

cracked, cut, abraded, or otherwise degraded.  

Replace terminals that are worn, discolored, or 

corroded.  Keep terminals clean and tight.

4. 

Do not alter or adjust any part of the 

equipment or its engine that is sealed by the 

manufacturer or distributor.  Only a qualified 

service technician may adjust parts that may 

increase or decrease governed engine speed.

5.  Wear ANSI-approved safety goggles, 

heavy-duty work gloves, and  

dust mask/respirator during service.

6.  Maintain labels and nameplates on the equipment.   

These carry important information.   

If unreadable or missing, contact 

Harbor Freight Tools for a replacement.

7.  Have the equipment serviced by a qualified repair 

person using only identical replacement parts.  

This will ensure that the safety of the equipment 

is maintained.  Do not attempt any service or 

maintenance procedures not explained in this 

manual or any procedures that you are uncertain 

about your ability to perform safely or correctly.

8.  Store equipment out of the reach of children.
9.  Follow scheduled engine and 

equipment maintenance.

Refueling:

1.  Do not smoke, or allow sparks, flames, 

or other sources of ignition around the 

equipment, especially when refuelling.

2.  Do not refill the fuel tank while the 

engine is running or hot.

3. 

Do not fill fuel tank to the top.   

Leave a little room for the fuel to expand as needed.

4.  Refuel in a well-ventilated area only.
5.  Wipe up any spilled fuel and allow excess 

to evaporate before starting engine. 

To prevent FIRE, do not start the engine 

while the smell of fuel hangs in the air.

 SAVE THESE INSTRUCTIONS.

Содержание 61169

Страница 1: ......

Страница 2: ...2VDC Two Pin Outlet Displacement 125cc Compression Ratio 8 5 1 Engine Type Horizontal Single Cylinder 4 stroke OHC Cooling System Forced air cooled Fuel Type 87 octane unleaded gasoline Capacity 1 35...

Страница 3: ...e WARNING marking concerning Risk of Eye Injury Wear ANSI approved safety goggles with side shields Read the manual before set up and or use Symbol property or Statement WARNING marking concerning Ris...

Страница 4: ...ending to use the generator for back up power 10 Do not operate the generator before grounding The generator must be earth grounded in accordance with all relevant electrical codes and standards befor...

Страница 5: ...nterference or pacemaker failure Caution is necessary when near the engine s magneto or recoil starter 27 Use only accessories that are recommended by Harbor Freight Tools for your model Accessories t...

Страница 6: ...speed 5 Wear ANSI approved safety goggles heavy duty work gloves and dust mask respirator during service 6 Maintain labels and nameplates on the equipment These carry important information If unreadab...

Страница 7: ...ratio will need to be adjusted by a qualified mechanic to allow efficient high altitude use and to prevent damage to the engine and any other devices used with this product Grounding 1 The Generator m...

Страница 8: ...evel The oil level should be up to the edge of the hole as shown 6 As needed add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recommended for general use 7...

Страница 9: ...ove the Choke to the START position To restart a warm Engine leave the Choke in the RUN position 3 Turn the Fuel Valve to the ON position Note After unpacking before first use slowly pull recoil handl...

Страница 10: ...n b The break in period will last about 25 hours of use DO NOT exceed 75 of the Generator s rated capacity during this period Change the Engine oil after this period Under normal operating conditions...

Страница 11: ...ry Charger 380 String Trimmer 350 Hedge Trimmer 500 Radio 50 Ten 75 Watt Light Bulbs 750 Figure A plug Load In Plug the power cord of the 120 volt appliance tool into the 120 volt AC Outlet on the Gen...

Страница 12: ...p the Engine in an emergency turn the Engine Switch off Under normal conditions use the following procedure to shut off the Generator 1 Unplug all electrical load devices from the Generator 2 Turn the...

Страница 13: ...alified technician service the equipment instead Cleaning Maintenance and Lubrication Schedule Note This maintenance schedule is intended solely as a general guide If performance decreases or if equip...

Страница 14: ...octane or higher unleaded gasoline 5 Then replace the Fuel Cap 6 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell...

Страница 15: ...1 Remove Access Panel from top of Generator see above 2 Disconnect spark plug cap from end of plug Clean out debris from around spark plug 3 Using a spark plug wrench remove the spark plug 4 Inspect t...

Страница 16: ...carburetor bowl and allow the fuel to drain c Open the fuel valve After all fuel has drained reinstall the drain bolt Tighten securely 3 LUBRICATION a Change engine oil b Clean out area around spark p...

Страница 17: ...ide of carburetor float chamber with screwdriver handle 8 Turn Choke to RUN position Remove spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke...

Страница 18: ...llow engine to warm up prior to operating equipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1...

Страница 19: ...M6 17 2 10a Right Crankcase Asm 1 11a Fuel Filter Asm 1 12a Spring 1 13a Cap 1 14a O Ring 1 15a Stud 2 16a Right Cover 1 17a Right Crankcase Gasket 1 18a Drain Plug 1 19a Oil Seal 19 8X30x5 1 20a Bol...

Страница 20: ...alve Cover Seal 1 15c Valve Cover 1 16c Flange Bolt M6 25 2 17c Flange Bolt M6 36 2 18c Cam Journal 1 Note When ordering parts from this diagram add a c suffix parts List and Diagram D Camshaft part D...

Страница 21: ...Asm 1 Note When ordering parts from this diagram add an e suffix parts List and Diagram F Air Cleaner and Carburetor part Description Qty 1f Carburetor Gasket A 1 2f Carburetor Asm 1 3f Carburetor Ga...

Страница 22: ...rter 1 3g Fan Cover 1 4g Bolt M5 20 4 5g Fan Cover Bushing 4 6g Screw ST4 8 16 F H 4 7g Recoil Cage 1 8g Cooling Fan 1 9g Shroud B 1 10g Shroud 1 11g Bolt M5 12 4 12g Shroud Bushing 4 13g Nut M5 2 Not...

Страница 23: ...g 1 10i Ignition Asm 1 11i Ignition Cap 1 Note When ordering parts from this diagram add an i suffix parts List and Diagram J Fuel Tank part Description Qty 1j Fuel Cap Asm 1 2j Fuel Filter 1 3j Rubbe...

Страница 24: ...l 1 7k Top Cover 1 8k Right Cover 1 9k Bolt ST4 2 13 1 10k Nut M8 8 11k Cover Plate 1 12k Bolt M8 12 4 13k Rear Damping Pad 2 14k Front Damping Pad 2 15k Chassis Asm 1 16k Bolt M6 16 4 17k Foot 4 18k...

Страница 25: ...13 2 5n U Rack 3 6n Rubber Foot 1 Note When ordering parts from this diagram add a n suffix parts List and Diagram p Control panel part Description Qty 1p Box 1 2p Screw M5 16 1 3p Screw M5 20 1 4p Re...

Страница 26: ...EMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPA...

Страница 27: ...erein HFT are pleased to explain the emissions control system warranty on your 2013 and later Small Off Road Engine herein engine Within the United States new off road spark ignition engines certified...

Страница 28: ...which are not authorized by HFT b Improper installation adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center c Failure to follow recommendatio...