Connecting 120V~ Loads to the Generator
Calculate power Draw:
Power draw can be calculated by multiplying
volts
and
amps
. The resulting number is
wattage
.
• Never exceed the rated maximum wattage for the Generator or any outlet amperage rating.
• Refer to appliance/tool owner’s manuals to determine the wattage of electrical load devices.
• Long power cords and extension cords draw additional power. Keep cord length at a minimum.
Wattage Estimates
Wattages listed below are estimates for that type of equipment only.
Check nameplate wattages on all loads before connecting to Generator.
This Unit Can power Any
One of the Following Items:
Running
Watts
Start-up
Watts
1/4 HP Air Compressor
600
900
1/6 HP Motor
500
800
3/8" Drill
400
600
Mini Refrigerator
400
700
Table/Box Fan
200
15 Amp Battery Charger
380
String Trimmer
350
Hedge Trimmer
500
Radio
50
Ten 75 Watt Light Bulbs
750
Figure A: plug Load In
Plug the power cord of the 120 volt appliance/
tool into the 120 volt AC Outlet on the Generator.
Plug in appliances from largest to smallest load.
Note: Do not allow the Generator to completely run
out of fuel with devices attached. A Generator’s
output may sharply spike as it runs out of fuel,
causing damage to attached devices.
OVERLOAD Light
Note:
The OVERLOAD light may turn on for a few seconds as a large device starts up.
This is normal for loads approaching the capacity of this Generator.
1. The total combined load through the outlet
on the Generator must not exceed the
rated maximum power of the unit.
2. If the OUTPUT light flashes,
the OVERLOAD light turns on, and
the Generator shuts off, it has overheated.
3. Turn Engine switch off,
disconnect all electrical devices, and
compare device requirements to Generator rating.
Move anything that may be limiting
Generator ventilation away.
4. Restart Generator (the OVERLOAD device will
automatically reset), and reconnect devices
while being careful to not overload Generator.
OUTpUT
OVERLOAD
OIL ALERT