Visually inspect the Auto Stop sensor for physical damage. Replace
if appropriate. Access the Service Access software (hardware
validation tests), and select the Auto Stop test (see section-5).
If the feature is enabled the P80 Auto Stop sensor test will count
the number of times the magnet crosses the sensor. The P10, P20 and
P30 consoles will display "USER DETECTED" if motion is detected from
the running deck or "NO USER DETECTED" if no motion is detected from
the running deck. If the Auto Stop test in the P80 did not count
steps or if the P10, P20 or P30 consoles displayed "NO USER
DETECTED", disconnect the Auto Stop cable from the Auto Stop sensor
and check for 5vDC between the red and black wire. If 5vDC is
present replace the Auto Stop sensor.