![Precor TRM10/GEN06 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/precor/trm10-gen06/trm10-gen06_service-manual_1595099062.webp)
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 60
With the incline below 15% (to allow room for lift travel),
connect an AC voltmeter between terminals 5 (black) & 6 (red) of
the INCLINE connector. See Figure above and below. Set the
treadmill in the manual program and press the INCLINE
key. The
AC voltmeter should read between 1.5 to 2.0 times the AC line
voltage. If this reading is significantly low, replace the lift
motor. Note that the AC line voltage reading will only be present
before an error condition is displayed.
o
If the capacitor is bad the lift motor must be replaced.
5
If a lift motor winding is bad, the lift will not operate in one or
both directions depending on the exact fault in the motor.
Содержание TRM10/GEN06
Страница 2: ......
Страница 23: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 21...
Страница 93: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 91...
Страница 139: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 137 Exploded View...
Страница 140: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 138...
Страница 141: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 139...
Страница 142: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 140...
Страница 143: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 141...