ProtEX-MAX PD8-7000 Explosion-Proof Temperature Meter Instruction Manual
4
Factory Defaults & User Settings ---------------------- 52
Troubleshooting Tips -------------------------------------- 53
Service ----------------------------------------------------- 54
Mounting Dimensions --------------------------------- 55
EU Declaration of Conformity ----------------------- 57
Table of Figures
Figure 1: Integrated ProVu Required Connections .. 13
Figure 2. Connector Labeling for Fully Loaded PD8-
7000 ...................................................................... 14
Figure 3. Power Connections ..................................... 14
Figure 4. Thermocouple Input Connections ............. 15
Figure 5. Three-Wire RTD Input Connections ........... 15
Figure 6. Two-Wire RTD Input Connections ............. 15
Figure 7. Four-Wire RTD Input Connections ............. 15
Figure 8. Average Temperature RTD Input
Connections ........................................................ 16
Figure 9: ProtEX-MAX Connections to a Serial
Converter ............................................................. 16
Figure 10. Three-Wire RS485 Connection ................. 16
Figure 11: RS-485 Wiring ............................................ 17
Figure 12: RS-485 Two-Wire Multi-Drop Wiring ........ 18
Figure 13. Relay Connections ..................................... 19
Figure 14. AC and DC Loads Protection .................... 19
Figure 15. Low Voltage DC Loads Protection ........... 19
Figure 16. F4 Digital Input Connections .................... 20
Figure 17. 4-20 mA Output Connections .................... 20
Figure 18. Interlock Connections ............................... 20
Figure 19: Digital I/O Connections ............................. 21
Figure 20. Acknowledge Relays w/Function Key or
Digital Input .......................................................... 37
Figure 21: General Four-Wire Network Connection .. 44
Figure 22: General Two-Wire Network Connection... 44
Figure 23: Enclosure Dimensions – Front View ........ 55
Figure 24: Enclosure Dimensions – Side Cross
Section View ......................................................... 55
Introduction
The ProtEX-MAX PD8-7000 offers all the functionality of the ProVu PD7000 as a fully FM, CSA,
ATEX, and IECEx approved explosion-proof product. It accepts a direct temperature input from a
wide range of temperature measurement devices (type J, K, T, E, R, S, B, N, and C thermocouples
and 100 or 1000 Ω platinum, 10 Ω copper, 120 Ω nickel RTDs). It displays the measured
temperature in either degrees Fahrenheit or degrees Celsius on a dual-line, 6-digit SunBright®
sunlight readable display. The meter includes automatic cold junction compensation for
thermocouples and the ability to average up to ten (10) RTD sensors. The PD8-7000 can be
equipped with up to four internal relays and a 4-20 mA analog output. It can be programmed and
operated without opening the housing by using the built-in SafeTouch® through-glass buttons or